Tag Archive for: MTBF
WhitepapersWhite paper – 40+ Year Reliability in Critical Power Electronics
40+ Year Reliability in Critical Power Electronics: The Premium SA Approach
Physics-of-Failure, DFR methodology, RAMS metrics and PHM — for directors of engineering, procurement and operations

Born in Barcelona, Powering the World
Introduction: From Unit Price to Total Cost of Ownership
In critical infrastructure — rolling stock, electrical substations, signalling systems, continuous-process plants — the cost of one hour of unavailability far exceeds the price of any electronic converter. Over the last decade, the fraction of total cost of ownership attributable to the acquisition price has fallen below 30% in railway and substation grid applications; the remaining 70% is split between energy consumed, scheduled maintenance, spare parts and, above all, unavailability.
The result is that the purchase decision has migrated from unit price to total cost of ownership. The real question is no
longer “how much does it cost?” but “how long will it last and how will you prove it?”
1. Why Power Electronics Fails — The Physical Mechanisms
Electronic components do not fail randomly: they fail through identifiable, modellable and predictable physical mechanisms. The Physics-of-Failure (PoF) methodology — which Premium SA adopts as primary reference, as opposed to the outdated MIL-HDBK-217F — classifies these mechanisms into four families:
1. Thermo-Mechanical Mechanisms
Dominant in power modules (IGBT, MOSFET, SiC). Every thermal cycle causes materials with different coefficients of thermal expansion (CTE) to expand and contract at different rates, accumulating plastic deformation in solder joints and bond wires.
- Solder fatigue: Coffin-Manson model: Nf ∝ ΔTj−n with n ≈ 5–7. Increasing Rth(j-c) → vicious circle of rising Tj and accelerating degradation
- Wire-bond lift-off: Main cause of wear-out failure in traction IGBT modules. Each lost wire increases current in remaining ones, accelerating the next failure
2. Electrical & Dielectric Mechanisms
Active semiconductors age through electrical causes, with no need for thermal cycles. Degradation accumulates during normal operation.
- TDDB: Gate oxide traps accumulate until resistive conduction path forms. Arrhenius model with electric field accelerator
- Electromigration: Black model with J² as main variable. Opens voids or creates shorts in metallisation traces
- Hot Carrier Injection (HCI): Particularly relevant in fast-switching SiC and GaN transistors
- NBTI/PBTI: Gradual transconductance gm reduction under bias at high temperature
3. Chemical & Environmental Mechanisms
Humidity, contaminants, salts and radiation present in any real installation.
- Corrosion and electrochemical migration: Dendrite formation (whisker effect) causing intermittent shorts. Peck model (humidity × temperature)
- Radiation-induced errors (SEU): Cosmic ray neutrons and alpha particles causing Single Event Upsets in memory cells. Mitigated by design: ECC, watchdogs, logical redundancy
4. Mechanical Mechanisms
In railway applications under EN 61373 (category 1B body-mounted), equipment absorbs 5–50 m/s² of random vibration over full life. Critical points: solder joints of heavy components (electrolytics, ferrites, transformers) and connectors. Design control: first mechanical PCB frequency clearly above dominant excitation range (>75 Hz).
2. The Bathtub Curve — Each Phase Calls for a Different Technique
Electronic components exhibit three recognised phases: infant mortality (high initial failure rate from latent manufacturing defects), useful life (low and approximately constant rate), and wear-out (rising rate from accumulation of physical mechanisms). A mature DFR process attacks all three simultaneously.
| Technique | Phase Addressed | When Applied | Premium SA Standard |
|---|---|---|---|
| HALT (Highly Accelerated Life Testing) | Design margin discovery | Design phase on prototypes | Combined temperature + vibration stresses beyond specification limits |
| HASS (Highly Accelerated Stress Screening) | Latent manufacturing defects | Production screening | Stress levels just below operating limit; 100% of production units |
| Burn-in | Infant mortality (left tail) | Post-production, pre-delivery | 4 h per unit at +60 to +80 °C; extendable to 8 h for long-interval programmes |
3. RAMS — The Contractual Language of Reliability
RAMS stands for Reliability, Availability, Maintainability, Safety — the four metrics with which a railway operator or grid DSO measure equipment suitability over its useful life. EN 50126 is the framework standard; EN 50128 and EN 50129 cover software and functional safety respectively.
Reliability
R(t) — probability of surviving to time t. Expressed as MTBF = 1/λ for exponential distribution, or by Weibull parameters (β, η) for wear-out phases. Premium SA calculates MTBF by PoF, not by parts-count (MIL-HDBK-217F).
Availability
A = MTBF / (MTBF + MTTR). For a substation converter with MTBF = 500,000 h and MTTR = 4 h: A ≈ 99.9992%. The key lever is not only increasing MTBF but also reducing MTTR.
Maintainability
Design levers: LRU architecture (front access, two captive screws, keyed connectors), built-in telemetry and self-test, RUL (Remaining Useful Life) estimation via PHM, and 40+ year spares continuity with quarterly obsolescence review.
Safety — EN 50128 / 50129
SIL (Safety Integrity Level) per IEC 61508. PFD (Probability of Failure on Demand) for standby safety functions. SIL 3–4 requires: redundancy, periodic self-test, MC/DC software coverage metrics, formal methods. Premium SA D4Co-SW methodology aligned with EN 50128.
4. The Premium SA DFR Process — Four Sequential Gates
The Design for Reliability (DFR) methodology — originated at the Center of Reliable Power Electronics (CORPE, Aalborg University) and adopted as an internal standard at Premium SA — structures development in four sequential gates with quantitative exit criteria:
| Gate | Objective | Key Activities | Exit Criterion |
|---|---|---|---|
| D2W (Design to Work) | Functional specification | Mission profile definition, requirements capture, architecture selection | Signed mission profile + functional test pass |
| D2F (Design to Function) | Derating and PoF analysis | Tj_max ≤ 80%, Vop ≤ 80%, thermal simulation, stress analysis | All derating targets met; no RPN > 80 open |
| D4R (Design for Reliability) | FMEA, FTA, HALT | FMEA bottom-up + FTA top-down; HALT protocol; Coffin-Manson solder analysis | RPN > 100 blocked; HALT limits documented; MTBF target verified |
| D4Co (Design for Compliance) | Qualification and FRACAS | HASS production screening; burn-in; EMC pre-compliance; EN 50155/EN 61373 qualification | All certifications obtained; FRACAS activated; customer RAMS deliverables signed |
5. FMEA, FTA and the Analytical Hierarchy
Once derating is established, reliability engineering identifies and mitigates dominant failure modes through three complementary analyses:
- FMEA/FMECA (Failure Mode and Effects Analysis): Bottom-up. RPN = Severity × Occurrence × Detection (1–10 scale). At Premium SA, any RPN >80 triggers a documented action plan; RPN >100 blocks the D4Co gate.
- FTA (Fault Tree Analysis): Top-down. Decomposes boolean combinations (AND/OR gates) that may cause system fault. Quantifies impact of redundancies; allows calculation of system-level MTBF.
- ETA (Event Tree Analysis): Inductive. Models scenarios and responses derived from a single initiating event. Useful for evaluating fault propagation in multi-state systems.
6. Keeping Reliability in Service — PHM, FRACAS and Lean Reliability
PHM — Prognostics and Health Management
The active technical frontier today is the transition from fixed-schedule preventive maintenance towards maintenance based on actual condition. In Premium SA converters:
- Real-time Tj estimation of semiconductors from Vce_sat and current, with case-temperature compensation
- Cumulative power-cycle counting with associated ΔTj, to predict RUL (Remaining Useful Life) by PoF models
- ESR monitoring of capacitors by ripple analysis
- Periodic export of operating data over communication bus to the operator’s supervisor, with P-F (potential-functional) profile
FRACAS — The Continuous-Learning Loop
Failure Reporting, Analysis and Corrective Action System: every field return is analysed at the appropriate level — LRU, board, component — root cause is identified, and the corrective action is propagated to design and production. The consequence is that the population of installed equipment improves over time rather than degrading. The problem detected in unit #150 is prevented in unit #151.
About Premium SA — Premium SA is a Barcelona-based manufacturer of power electronics converters for railway, industrial and energy applications. Founded in 1981, with more than 900 standard product designs and over 40 years of operational experience, Premium SA supplies DC/DC converters, DC/AC inverters, AC/AC frequency converters, battery chargers, rectifiers and UPS systems from 50 W to 72 kW. All products are designed and manufactured at the Premium SA plant in Barcelona, with capability for EN 50155, EN 50121-3-2, EN 45545-2 and EN 61373 certification. Premium SA serves OEMs and system integrators across Europe through direct sales and a network of specialist distributors — ELIPSE (Benelux), Elma Electronic (Switzerland), RELEC Electronics (United Kingdom), DACPOL (Poland and Central Europe) and ANDA-OLSEN (Scandinavia).
Premium SA · Barcelona, Spain · info@premiumpsu.com · +34 932 232 685 · www.premiumpsu.com
Application NotesAdvances in Power Electronics: Reliability and RAMS
Advances in Power Electronics: Reliability and RAMS
From the potentiometer to digital and laser trimming, from the electrolytic capacitor to software-based ripple control — a roadmap to 40-year reliability in critical infrastructure and railway
Executive Summary
Industrial and railway power electronics is going through a quiet but decisive transition: the replacement of electromechanical components and manual trimming techniques with solid-state architectures and deterministic calibration processes. Three levers drive this transition — the progressive elimination of the potentiometer, the reduction or elimination of the electrolytic capacitor, and the introduction of laser trimming on thick-film technology as the precision adjustment method in production. Each one targets a specific failure mechanism that historically limited converter service life; combined, they explain why a well-engineered unit today can be committed to an MTBF an order of magnitude higher than its fifteen-year-old predecessor at the same power rating.
This article walks through the three levers, ties them together with the Design for Reliability (DFR) methodology applied at Premium SA — mission profile, derating, FMEA, HALT/HASS, burn-in, FRACAS — and connects the result with the RAMS requirements of railway (EN 50126 / EN 50128 / EN 50129) and of critical grid infrastructure. The thesis is simple: 40-year reliability cannot be bought, it has to be designed; and the technological advances described here are the tools that make such a design viable.
1. The Paradigm Shift: From Reliability as Outcome to Reliability as Design Decision
For decades, the reliability of a power converter was measured after the fact. A unit was designed against a functional specification, manufactured, delivered, and the field failure rate was observed in service. If the number was unacceptable, the design was reworked. This “test-and-fix” approach has a well-known structural cost: correcting a reliability problem scales roughly 1× at schematic stage, 10× at layout, 100× at qualification testing, and grows by several additional orders of magnitude when the issue surfaces in a deployed fleet. The economics simply do not work in sectors with 30-year vehicle or substation lifecycles.
Design for Reliability (DFR), originated at the Center of Reliable Power Electronics (CORPE, Aalborg University) and adopted as the internal standard at Premium SA, inverts this order: reliability is set as a quantitative target at project kickoff — mission profile, target MTBF, service life, environmental conditions, thermal cycling — and the entire development process is structured to meet that number. The associated paradigm shift is the migration from handbook statistical models (MIL-HDBK-217F) toward a Physics-of-Failure (PoF) approach, grounded in the actual physical failure mechanisms: thermal fatigue of solder joints and wire bonds (Coffin-Manson), electrolyte evaporation under Arrhenius, electromigration, corrosion, mechanical fatigue of fasteners.
2. Goodbye to the Potentiometer: Digital Adjustment and Laser Trimming
2.1 The potentiometer as a concentrator of failure modes
The mechanical potentiometer has been the standard component for production calibration and field maintenance adjustments in power converters for half a century. Its appeal is obvious: it allows fine tuning of an analogue value (a voltage reference, a protection trip point, a gain) without changing components or reprogramming anything. But that very flexibility hides a concentration of failure mechanisms unmatched by any other passive component on the converter: mechanical wear of the resistive track; sensitivity to vibration (EN 61373 Cat. 1B); sensitivity to humidity and contamination; single point of intermittent failure via the wiper contact; and human risk in the adjustment — any manual field intervention is an opportunity to introduce an untraced calibration error.
The question is not whether a potentiometer will fail, but when. In a unit with a 30-year service life and a railway or substation mission profile, the answer is invariably “before the end”.
2.2 Replacement strategy 1 — digital potentiometer and parametric calibration
The first replacement strategy moves the adjustment to the digital domain. The analogue reference no longer comes from a trim resistor divider but is generated by software from a parameter stored in the microcontroller’s non-volatile memory or in an external EEPROM. Calibration is performed once in production, on a calibrated and traceable test bench, and is recorded against the unit’s serial number, operator, date and process signature.
| Characteristic | Mechanical potentiometer | Parametric digital calibration |
|---|---|---|
| Adjustment mechanism | Wiper sliding on resistive track | Read parameter from EEPROM/Flash |
| Temporal stability | Cumulative wear, vibration, humidity | Only DAC/MCU drift (ppm/°C) |
| Traceability | None beyond manual procedure | Digital log signed by serial number |
| Maintenance risk | Misalignment by human intervention | Protected calibration (digital signature) |
| Dominant failure mode | Intermittent wiper opening | MCU failure or EEPROM corruption |
| Typical function MTBF | < 50,000 h in harsh environments | > 500,000 h (silicon-limited) |
2.3 Replacement strategy 2 — laser trimming on thick film
Thick-film technology has matured to make laser trimming a standard industrial process. Modern resistive pastes (RuO₂ and advanced ceramic compounds) provide stable resistors up to 300 °C continuous operation, with temperature coefficients below ±25 ppm/°C in precision grades. Components produced this way are surge-resistant, mechanically robust and their value does not drift over time under normal operating conditions.
2.4 When to choose each strategy
| Function to be set | Preferred strategy | Reason |
|---|---|---|
| OVP/OCP/OTP trip points | Digital calibration | Mandatory traceability; RAMS audit |
| Control-loop gain | Deterministic design (no trim) | No post-design adjustment at all |
| Internal voltage reference | Laser-trimmed precision resistor network | Absolute stability without firmware involvement |
| Shunt current sensor | Laser-trimmed integrated resistor | 0.1 % tolerance with no temporal variation |
| Instrumentation amplifier gain | Laser-trimmed R2R network, IC-integrated | Current industry standard |
| Per-unit offset compensation | One-shot digital calibration in production | Covers natural silicon dispersion |
| Field-variable operating point | Signed digital parameter | Zero physical manual intervention |
The practical conclusion is that in a modern Premium SA control board there should be no physical potentiometer at all. Factory adjustments are laser or digital; field adjustments are digital-only, protected by signature; control loops are deterministic by design.
3. Reducing and Eliminating the Electrolytic Capacitor
3.1 The electrolytic as the Achilles heel of the DC bus
If the potentiometer is the Achilles heel of calibration, the aluminium electrolytic capacitor is the Achilles heel of the DC bus. It is typically the component that fixes the service-life ceiling of a power converter, because it combines five awkward properties: service life intrinsically limited by electrolyte evaporation (life ÷2 every +10 °C); ESR growing with ageing; capacitance decreasing to ~80 % at end-of-life; sensitivity to ripple current (Pdis = Iripple² × ESR → self-heating → accelerated ageing); and mechanical sensitivity requiring rigid restraint under EN 61373.
3.2 Premium SA strategy — long-life 105 °C capacitors
The first line of defence, when an electrolytic is unavoidable due to capacitance density, is aggressive part selection. Premium SA standardises on aluminium capacitors rated to 105 °C (some ranges to 125 °C in critical applications) with manufacturer-declared service life of 8,000 to 12,000 hours at maximum temperature — equivalent, by Arrhenius, to over 100,000 hours when operated at 50 °C. Combined with the Premium SA derating policy — Vop ≤ 80 % of Vrated, Iripple_real ≤ 80 % of Iripple_rated, Ta_cap < 85 °C in worst case — this pushes the ageing curve well below the product’s service-life horizon.
But “pushing” is not “eliminating”. As long as there is an electrolytic on the DC bus, there is a wear-out component that defines the slope of the bathtub curve at end of life.
3.3 Why digital ripple control changes the rules
| Aspect | DC bus with electrolytics | DC bus with film + digital control |
|---|---|---|
| Dominant component | Aluminium electrolytic 105 °C / 12,000 h | Polypropylene film, > 200,000 h |
| Dominant failure mechanism | Electrolyte evaporation (Arrhenius) | No significant wear-out mechanism |
| Thermal sensitivity | Life ÷2 every 10 °C | Minimal across operating range |
| Capacitance with ageing | Drops to 80 % at end of life | No significant drop |
| ESR evolution | Grows ×2 by end of life | Stable across full service life |
| DC-bus function MTBF | Limited by the electrolytic | Limited by semiconductors |
| TCO | Low BOM, high service cost | Higher BOM, lower service cost |
3.4 The measurable impact — MTBF, MTTR, reliability
Removing the electrolytic from the DC bus simultaneously moves all three metrics that matter in critical infrastructure. MTBF rises — we have observed typical 5× to 10× improvements in converters where the electrolytic was the limiting factor. MTTR drops because the LRU is replaced less frequently and the spare-parts catalogue is simplified. Reliability R(t) approaches 1 asymptotically over the full 30-year horizon, instead of degrading in the last 10 years due to electrolytic wear-out. These effects are particularly valuable where downtime carries contractual cost: an electrical substation where a fault triggers DSO penalties, or a rolling-stock fleet where a withdrawal from service breaks the operator’s timetable.
4. Design for Reliability — the Methodology that Ties the Advances Together
The two technological levers above are necessary but not sufficient conditions. 30-year reliability also requires a development process that integrates and verifies them. The Premium SA DFR methodology structures the design across four sequential gates — D2W (Design to Work), D2F (Design to Function), D4R (Design for Reliability) and D4Co (Design for Compliance) — each with quantitative exit criteria.
4.1 Mission profile and derating as non-negotiable input
The first artefact of any Premium SA project is the mission profile: maximum and minimum ambient temperature, daily thermal cycles, cyclic humidity, altitude, vibration, expected number of starts over the service life, frequency of S2 supply-interruption events. Without this input, no PoF calculation has any meaning. With it, derating decisions become quantitative.
| Component family | Premium SA derating rule | Physical justification |
|---|---|---|
| Power semiconductors | Tj ≤ 80 % of Tj_max (≤ 125 °C Si, ≤ 150 °C SiC) | Coffin-Manson on wire bonds: Nf falls as (ΔTj)^β |
| Aluminium electrolytics | Vop ≤ 80 % Vrated, Iripple ≤ 80 % rated | Arrhenius law on electrolyte evaporation |
| MLCC capacitors | Vop ≤ 50 % Vrated | Capacitance loss vs DC bias on X5R/X7R |
| Resistors | Pop ≤ 60 % Prated, Vop ≤ 80 % Vrated | Intra-component insulation |
| Connectors | I ≤ 70 % Irated per contact | Contact heating under fatigue |
| Insulation (creepage/clearance) | ≥ 1.5× minimum per EN 50124-1 | Margin against long-term contamination |
4.2 FMEA, FTA and the failure-mode hierarchy
Once derating is set, reliability engineering concentrates on identifying and mitigating the dominant failure modes through two complementary analyses. FMEA (Failure Mode and Effects Analysis) works bottom-up: for each component and each interface, possible failure modes, their causes and their effects are enumerated, with a Risk Priority Number assigned (RPN = Severity × Occurrence × Detection, 1–10 scale). At Premium SA, any RPN > 80 triggers a documented action plan, and RPN > 100 blocks the D4Co gate. FTA (Fault Tree Analysis) works top-down: it starts from the system failure and decomposes the Boolean combinations (AND/OR gates) that can cause it, allowing the impact of redundancies to be quantified and improvements to be prioritised by sensitivity factor.
4.3 The bathtub curve — each phase calls for a different technique
| Bathtub phase | Dominant cause | Control strategy |
|---|---|---|
| Infant mortality (0–500 h) | Latent manufacturing defects: cold solder, contamination, assembly errors | HALT in design + HASS/burn-in in production + 100 % AOI/ICT |
| Useful life (500–50,000 h) | Random events: overvoltage, ESD, mains transients | Protections (OVP/OCP/OTP), derating, preventive FMEA |
| Wear-out (> 50,000 h) | Accumulated damage: thermal fatigue, electrolyte degradation, corrosion | Low Tj_max, reduced ΔTj, eliminate electrolytics, condition monitoring |
4.4 HALT, HASS and burn-in — what each one does
These three techniques are often confused, and they tackle different problems at different moments. HALT (Highly Accelerated Life Testing) is a limit-exploration test in the design phase: combined stresses (temperature + vibration) are progressively applied beyond the specification, until the operational and destruct limits of the product are found. It is not a qualification test, it is a discovery test — the output is the knowledge of how much margin we hold. HASS (Highly Accelerated Stress Screening) is a production-phase variant, with stress levels chosen just below the operational limit, used to detect latent manufacturing defects without consuming the product’s service life. Burn-in operates the product under controlled temperature (typically +60 to +80 °C) and load for several hours to screen the infant-mortality phase. Premium SA standardises 4 h of burn-in per unit, extended to 8 h on programmes with long maintenance intervals.
The three are complementary: HALT explores; HASS screens in production; burn-in cuts the left tail of the bathtub curve. Applied together, the failure rate during the first year in service drops to a fraction of the value without these techniques.
5. The Other Component that Also Ages — the Software
Any modern converter with digital calibration, predictive ripple control, complex protections and communication with the network supervisor carries firmware of growing complexity. From the function-reliability standpoint, this firmware is just another component of the system — and like any other component, it can be the root cause of a failure that compromises availability. The difference is that software does not age physically, but confidence in it erodes if there is no disciplined verification and validation process.
5.1 V-Model and EN 50128 as the framework for railway firmware
The reference standard for railway-application software is EN 50128, part of the EN 5012x family (railway RAMS). Its central element is the V-Model: each level of specification (system requirements, software requirements, architectural design, module design, code) corresponds to a verification level (unit testing, integration testing, system testing, acceptance testing). Each SSIL (Software Safety Integrity Level, levels 1 to 4 plus Basic Integrity) imposes mandatory techniques: formal reviews, static analysis, specific coverage metrics.
| SSIL level | Typical converter application | Mandatory EN 50128 techniques |
|---|---|---|
| Basic Integrity | Functions unrelated to safety | Code review, functional testing |
| SSIL 1-2 | Cabin auxiliaries, monitoring | MISRA C static analysis, unit-test I/O coverage |
| SSIL 3 | Traction converters not brake-critical | MISRA + decision coverage + timing analysis |
| SSIL 4 | Active safety functions (e.g. brake inhibition) | MC/DC coverage, formal models, redundancy |
5.2 MISRA C, MC/DC and why they matter
MISRA C:2012 is the de facto standard for embedded firmware in C in critical systems. Its 143 rules (16 mandatory, 111 required, 16 advisory) cover language patterns that have historically been a source of defects: pointer aliasing, implicit conversions, undefined behaviour, dynamic memory management. Applying MISRA with static analysis (PC-lint, Coverity, Polyspace) removes a whole class of defects before execution. MC/DC (Modified Condition/Decision Coverage) is the most demanding coverage criterion routinely applied in certification: it requires that each individual condition within a Boolean decision independently affects the result of the decision. For a decision with n conditions, the minimum number of MC/DC tests is n+1, against the 2n required by combination coverage.
5.3 HIL and firmware verification on real hardware
The technique that closes the verification loop is HIL (Hardware-in-the-Loop). The firmware runs on the real microcontroller, but the input signals (voltage, current and temperature sensors) are synthesised by a real-time simulator that emulates the behaviour of the DC bus, the transformer, the motor or the load. This allows thousands of scenarios to be executed — including sensor failures, mains transients, short-circuits — with no physical risk to the equipment or to the test bench. A well-designed HIL programme catches hardware/software integration defects that no unit test could capture.
6. RAMS — the Metric that Ties Everything Together
RAMS stands for Reliability, Availability, Maintainability, Safety — the four metrics a railway operator or a grid DSO uses to judge the suitability of a unit across its service life. EN 50126 is the framework standard; EN 50128 and EN 50129 cover software and functional safety respectively.
6.1 The full R-A-M-S quadrant
| Metric | Operating definition | Dominant design lever |
|---|---|---|
| Reliability | Probability of fault-free operation across t | Component selection, derating, wear-out elimination |
| Availability | Fraction of time the system is operational | MTBF + MTTR; redundancy where applicable |
| Maintainability | Ease and speed of diagnosing and repairing | LRU design, telemetry, FRACAS, parts continuity |
| Safety | Absence of unacceptable risk | FTA, safe failure modes, software SSIL, redundancy of critical functions |
6.2 FRACAS — the continuous learning loop
FRACAS (Failure Reporting, Analysis and Corrective Action System) is the process by which every field return is analysed at the appropriate level — LRU, board, component — the root cause is identified, and the corrective action is propagated back to design and production. Premium SA runs FRACAS as a closed loop between Quality, Aftersales and R&D. The consequence is that the fleet population improves over time, rather than degrading: the issue detected in unit #150 is prevented in unit #151.
6.3 PHM and the move to predictive maintenance
The active technical frontier today is PHM (Prognostics and Health Management): the transition from fixed scheduled maintenance toward maintenance based on the actual condition of the equipment. In Premium SA converters we progressively implement: real-time Tj estimation of power semiconductors from Vce_sat and current; cumulative power-cycle counting with the associated ΔTj to predict RUL (Remaining Useful Life) via PoF models; capacitor ESR monitoring by ripple analysis; and periodic export of operational data to the operator’s supervisor over the communications bus. The result is that the operator no longer has to choose between excessive preventive maintenance and late corrective maintenance — the equipment reports how much life is left.
7. Synthesis: the Concrete Levers that Make 30-Year Reliability Viable
| Technological lever | Failure mode it removes | RAMS effect |
|---|---|---|
| Eliminating the potentiometer (digital + laser) | Wiper wear, vibration/humidity drift, human error in maintenance | Raises R, lowers MTTR |
| Reducing/eliminating the electrolytic (digital control + film) | Arrhenius wear-out of electrolyte | Raises MTBF 5–10×; flattens bathtub tail |
| Selection of 105–125 °C long-life electrolytics (where unavoidable) | Accelerated Arrhenius ageing of the limiting component | Pushes wear-out beyond the 30-year horizon |
| DFR + mission profile + derating | Random faults and overstress in the useful-life phase | Raises R in the central area of the curve |
| HALT in design + HASS/burn-in in production | Latent manufacturing defects (infant mortality) | Flattens the left tail of the bathtub curve |
| Software V&V (V-Model, MISRA, MC/DC, HIL) | Systematic firmware faults | The component that closes the case for a 30-year claim |
| LRU design + FRACAS + 30-year parts continuity | High MTTR and mid-life obsolescence | Raises A via the MTTR lever; protects the full lifecycle |
| PHM + condition monitoring | Inefficient maintenance (excessive preventive or late corrective) | Optimises total cost of ownership |
About Premium PSU — With over 40 years of experience, Premium SA designs and manufactures custom power converters in Barcelona for railway, energy, industrial, data center and defence applications.
Application Notes, Data CenterEngineering the Power Stack for AI Data Centers
Engineering the Power Stack for AI Data Centers
Custom mission-critical power electronics for AI factories, HPC clusters and hyperscale data centres — >97% efficiency, >1 kW/L density, MTBF >10⁶ h
Three barriers between AI and reliable power
Generative AI and HPC workloads are creating unprecedented demand for power infrastructure. Rack densities are growing 10× in five years. Hyperscale operators demand Titanium-class efficiency. AI factories tolerate zero downtime. Three barriers define the engineering problem — and all three must be solved simultaneously.
Efficiency: >97%
Titanium-class efficiency at every conversion stage. Every percentage point saved at 1 MW means 10 kW less heat — and a real capex reduction in cooling infrastructure.
Power density: >1 kW/L
Rack density is growing from 10–15 kW/rack to 200+ kW/rack by 2028. WBG semiconductors (SiC, GaN) and planar magnetics are the only viable path to meet these targets.
Reliability: >10⁶ h MTBF
AI factories run 24/7 with zero tolerance for downtime. Physics-of-Failure design, RAMS analysis and thermal budget management are non-negotiable engineering requirements.
Mission-critical power engineering, now for AI infrastructure
Premium PSU is not entering the data centre market from zero. We are transferring over 40 years of engineering experience from railway traction (EN 50155, EN 61373), defence and grid infrastructure — sectors where failure is simply not an option — into a market that now demands exactly those same standards.
| Capability | Focus | What it means in practice |
|---|---|---|
| WBG semiconductors | SiC · GaN · Ga₂O₃ | Baliga FOM-driven device selection. SiC for high-blocking-voltage stages; GaN for high-frequency switching. Gate-driver design, EMI management and long-term reliability qualification in-house. |
| Thermal engineering | RAMS · phonon engineering | 55% of power electronics failures are thermally driven. We apply Coffin-Manson fatigue modelling, thermal budget allocation and advanced substrates (Si₃N₄, AlN) from prototype to production. |
| Digital control | FPGA · SoC · predictive control | High-bandwidth digital loops, model-based design (MiL→SiL→HiL). Real-time telemetry via PMBus, SNMP, Modbus and REST. Full DCIM integration out of the box. |
| Passive components | Magnetics · capacitors | Custom inductors and transformers with nanocrystalline/ferrite cores. Elimination of electrolytic capacitors in critical paths — historically 35% of field failures. |
CPD-Ready 125V DC Kit — from pilot to hyperscale
Turn-key power infrastructure for AI compute, designed for native OCP Open Rack v3 (ORv3) architecture and full DCIM integration. Available in four power configurations — 20, 40, 60 and 72 kW — to match rack density targets from edge to AI factory scale.
- N+1 redundancy: hot-swap modules with seamless failover — zero downtime during maintenance windows.
- OCP ORv3 compliant: native support for the Open Compute Project Open Rack v3 architecture.
- Unified telemetry: SNMP / Modbus / REST — full integration with DCIM platforms.
- Pre-validated EMC: CE, IEC 62368-1, UL ready — integrated EMC-checked BOM.
- WBG switching stages: SiC-based conversion for >95% efficiency at full load.
- Co-development ready: custom configurations of voltage, form factor, firmware and interface.
Standard catalogue models for data centre architecture
| Model | DC application | Key adaptation | Power range |
|---|---|---|---|
| CKR-3600 | Modular 48V front-end rectifier | ≥97% eff., OCP ORv3 hot-swap, PMBus/SNMP | Up to 3.6 kW/module |
| CRS-2000 / 3000 | DC-DC mid/high power (48V ↔ 380V) | PMBus telemetry, >1 kW/L density | 2–3 kW |
| ODS-1500 / 3000 | AC/DC isolated front-end, edge | Modular scaling, >95% peak, Titanium | 1.5–3 kW |
| EPS-200 / 2000 | DC UPS — edge and critical rooms | Li-ion modular, bidirectional, SNMP | 200 W – 2 kW |
| ODX / OVX-6000 | Resilience inverters and microgrid | 19″ rack, remote control + telemetry | Up to 6 kW |
Over 40 years engineering power where failure is not an option
Our engineering credentials come from the most demanding industrial applications. Every methodology we apply in AI data centre projects — Physics-of-Failure, RAMS, thermal budget analysis — has been validated under real-world mission-critical conditions:
- Railway traction and high-speed rail: converters and inverters qualified to EN 50155, EN 61373 and EN 45545-2, including cold-start designs for −40 °C arctic operation and cross-border certification management. The same thermal and reliability design methodology applies to AI rack power.
- Urban rail systems: full RAMS analysis and EN 61373 vibration qualification, with rapid prototyping cycles.
- Grid infrastructure: modular inverter deployments across distribution networks. Grid-grade reliability and modular architecture are directly applicable to DC microgrid and AI campus designs.
Power electronics for AI data centres — technical Q&A
What power electronics does Premium PSU offer for AI data centres?
Premium PSU offers custom power electronics for AI data centres, including the CPD-Ready 125V DC Kit (20/40/60/72 kW, OCP ORv3 compliant), modular 48V rectifiers (CKR-3600), DC-DC converters (CRS-2000/3000), AC/DC isolated front-ends (ODS-1500/3000) and DC UPS systems (EPS-200/2000). All products feature SiC/GaN WBG switching for >97% efficiency, PMBus/SNMP/REST telemetry and N+1 redundancy design.
Is Premium PSU OCP ORv3 compliant?
Yes. The CPD-Ready 125V DC Kit is designed for native OCP Open Rack v3 (ORv3) architecture, supporting hot-swap modules, N+1 redundancy and full DCIM integration via PMBus, SNMP and REST interfaces. Premium PSU actively monitors OCP specifications and roadmaps to maintain alignment.
What is the MTBF of Premium PSU power supplies for data centres?
Premium PSU standard platforms achieve MTBF >10⁶ hours, validated through Physics-of-Failure (PoF) design methodology and RAMS (Reliability, Availability, Maintainability and Safety) analysis applied from day one of each project. Thermal budget allocation, Coffin-Manson fatigue modelling and elimination of electrolytic capacitors in critical paths are standard practice.
Can Premium PSU co-develop custom power solutions for AI infrastructure?
Co-development is at the core of how Premium PSU works. We assign dedicated engineers, run co-simulations, and optimise thermal and electrical budgets together with the customer. An NDA is signed on day one. Prototype delivery in under 14 weeks is our demonstrated standard. Custom configurations include voltage levels, form factors, firmware, communication interfaces and mechanical integration.
What efficiency class do Premium PSU AI data centre products achieve?
Premium PSU products target ≥97% efficiency at rated load, meeting Titanium-class requirements (80 PLUS Titanium, ≥96% at 50% load, ≥94% at 20% load). WBG SiC-based switching stages and planar magnetics are the primary enablers. Efficiency is guaranteed across the full operating temperature range for data centre environments.
What certifications do Premium PSU AI data centre products carry?
Products are certified or in certification for IEC 62368-1, CE (EU), UL (North America) and Energy Star. The CPD-Ready 125V DC Kit also targets 80 PLUS Titanium qualification. EMC compliance (CISPR 32, IEC 61000) is validated in-house at Premium PSU’s EMC laboratory in Barcelona.
About Premium PSU
Premium PSU (Premium SA) designs and manufactures custom power supplies and power converters in Barcelona, with over 40 years of experience in railway, energy, industrial, data centre and defence applications.
Talk to our engineering team
Discuss your power conversion requirements with Premium PSU.
Application Notes, WhitepapersSimulation and Test Tools That Ensure Success from the First Delivery
Simulation and Test Tools That Ensure Success from the First Delivery
How Premium SA builds custom power supplies and conversion systems that work at the first prototype

Born in Barcelona, Powering the World
Executive summary
The custom power electronics project for critical sectors — railway, defence, energy, infrastructure — does not allow the iterative cycle of the catalogue product. Production runs are short, deadlines are contractually binding, and the first prototype delivered to the customer must operate within specification. Massive hardware iteration is not an economically or temporally viable option.
Premium SA has developed an integrated simulation and test chain that systematically reduces the risk of the first prototype. The philosophy is direct: each hour of well-formulated simulation saves between five and ten hours of physical bring-up, and every fault detected in the modelling phase prevents costs that multiply exponentially when they appear in production or in the field.
The D2x methodology: five phases, one chain. The chain is built upon Premium SA’s proprietary D2x methodology — D2W (Design to Win), D2F (Design to Fabrication), D2C (Design to Cost), D4R (Design for Reliability) and D4Co (Design for Compliance / Component) — with quantitative stage-gates between phases and a V-Model that links each requirement with its verification evidence.
1. The custom project challenge: no second chance
Custom equipment is born from a tender specification: 15 kV DC in a railway substation, passive cooling in a deployable defence converter at −40 °C, a form factor for a traction cabin that does not allow a single additional millimetre. Each of these requirements eliminates entire families of catalogue solutions and forces design from the topology level upwards.
The operational consequence is severe: the first prototype delivered to the customer — typically between week four and week six of the project — is validated against the entire contract, not against a simplified version. Any deviation appearing in that validation has three possible outcomes, all costly: partial redesign with timeline replanning, acceptance of contractual penalties, or batch rejection with replacement.
Production runs are short — 50 to 500 units is a typical range in railway and defence — and the product learning curve runs out before it covers the cost of iteration. Success at the first prototype is not a desirable goal; it is the minimum threshold of economic viability.
The key metric: first-pass DVT approval rate. In projects where stages are shortened due to schedule pressure, this indicator drops rapidly and drags timelines and margins with it. Applying the simulation chain in full is what protects it.
2. The pre-prototype simulation chain
Pre-hardware verification is structured in four layers covering the four dominant fault vectors in power electronics: electrical behaviour in transients, thermal dissipation, electromagnetic compatibility and digital control. The four layers run in parallel and intersect at quantitative validation points.
2.1 Electrical modelling: SPICE / PLECS / Simulink
The first layer is the power circuit model. Standard tools — SPICE for detailed switching analysis, PLECS or Simulink for averaged models and full-system simulation — allow verification, before manufacturing the first PCB, that the closed control loop is stable across the full operating range, that waveforms at critical nodes do not exceed semiconductor voltage margins, and that calculated losses are consistent with the available thermal dissipation.
For topologies using wide-bandgap semiconductors (SiC, GaN), accurate modelling of packaging parasitic effects is decisive. A use case of the European ALL2GaN research project has documented how the parasitic inductance of the power loop conditions snubber sizing in 3 kW/48 V totem-pole rectifiers achieving 97.5% efficiency and 40 W/in³ density: without an electrical model that captures the inductance of the TOLL package versus PG-DSO-20, the sizing falls outside the optimum.
2.2 Thermal CFD simulation: from chip to system
The second layer covers the thermal domain. CFD simulation enables characterisation at three levels of detail: chip-level dissipation and junction-to-case of the semiconductor; air or liquid circulation in the complete product; and heat transfer with the environment — cabin, cabinet, outdoor. We cover this domain in more detail in our article on thermal design in power electronics.
For demanding power densities — current OCP servers for AI workloads must dissipate hundreds of kilowatts per rack, with the most demanding variants approaching local heat fluxes above 700 W/cm² in active areas — integrated liquid microchannel solutions with dielectric coolant, in fraction-of-a-millimetre channel geometries, are already production-ready technology.
Cross-validation between the electrical model (which delivers the loss map per component) and the thermal model (which delivers the temperature map) closes the first cycle: an operating point with plausible losses but unacceptable temperature forces a topology revision, not an oversizing of the dissipation.
2.3 EMC pre-compliance simulation
The third layer is electromagnetic compatibility. A pre-compliance session in a semi-anechoic chamber typically costs several thousand euros and consumes calendar days; discovering a radiated-emissions failure at that stage, with the product already wired, is one of the most damaging scenarios for a custom project.
Modern EMC simulation tools — Method of Moments (MoM) solvers for radiated emissions, cable-bundle models for conducted emissions, PCB-specific simulators for ground-plane resonances — allow prediction of product behaviour against the applicable standards (CISPR 32, EN 50121-3-2 for railway, MIL-STD-461 for defence) before manufacturing. The Premium SA criterion sets a minimum design margin of 6 dB with respect to the applicable limits; any spectrum point that falls inside that margin in simulation triggers a design iteration before manufacturing.
2.4 MATLAB / Simulink: digital control validation
The fourth simulated layer covers the digital control loop. MATLAB and Simulink allow verification of the stability of voltage, current and temperature loops across the full load range, identification of operating points with insufficient phase margin, and sizing of compensators before implementing them in firmware. Automatic C code generation from the Simulink model reduces the risk of discrepancy between what is simulated and what is deployed.
This layer becomes particularly relevant when control must be certified at functional safety level — SIL2 or SIL3 according to EN 50128 for railway, ASIL-B or ASIL-C according to ISO 26262 for automotive. Traceability between the safety requirement, the Simulink model, the generated code and the associated test is both a normative requirement and a quality practice.
3. Quantitative reliability analysis: D4R
Reliability is not only verified on the bench; it is designed. Quantitative reliability analysis — embodied at Premium SA in the D4R methodological block — makes it possible to commit to MTBF figures backed by model and evidence. Our white paper on reliability in critical power electronics develops this approach further.
3.1 MTBF calculation
MTBF calculation at Premium SA follows the standards accepted by each sector: Telcordia SR-332 (formerly Bellcore) and MIL-HDBK-217F for the Anglo-Saxon and defence markets; Siemens SN29500 for European industrial customers; IEC 61709 when required by the customer; FIDES for sectors with particular environmental severity requirements.
For topologies using wide-bandgap semiconductors, derating factors are particularly relevant. SiC allows junction operation at 200 °C, and GaN between 175 °C and 200 °C; however, standard practice in custom projects is to work with a derating of 30 to 50% on datasheet limits. The difference between operating a SiC MOSFET at Tj = 150 °C versus Tj = 175 °C, all else being equal, roughly doubles the failure rate.
3.2 FMEA: systematic risk ranking
FMEA is applied to both product design (Design FMEA) and the manufacturing process (Process FMEA). For each identified failure mode, three dimensions are assessed — severity, probable occurrence and detectability — giving a Risk Priority Number (RPN) as the product of the three. Premium SA practice sets two thresholds: no failure mode with severity 9 or 10 (out of 10) can leave the FMEA without documented corrective action, and any mode with an RPN above 100 enters the verification plan with a specific test.
3.3 FTA: top-down tree from the effect
Fault Tree Analysis works in the opposite direction to FMEA: it starts from a feared event — loss of power output, dangerous voltage emission to the load — and descends to identify the combinations of elementary failures that can produce it. The quantitative analysis, fed with component failure rates, allows calculation of the probability of the feared event and verification that it meets contractual or normative objectives — a PFH below 10−7 for SIL3, for example. FMEA and FTA are complementary: FMEA is exhaustive bottom-up; FTA is analytical top-down.
4. Physical testing: DVT, HALT and HASS
Simulation reduces uncertainty but does not eliminate it. The physical test plan closes the flow by verifying model predictions against reality and characterising the product against failure modes the model does not capture.
4.1 DVT: Design Verification Testing
DVT is the complete verification battery for the contractual product requirements: nominal and transient electrical behaviour, output regulation across the full load range, thermal behaviour under nominal and derating conditions, EMC margins with respect to the applicable standard, mechanical tests — vibration, shock, thermal cycling — and behaviour under simulated environmental faults. Standard practice runs DVT on three units; all three must pass all tests without rework.
4.2 HALT and HASS: accelerated filters
HALT (Highly Accelerated Life Testing) takes the product beyond operational conditions — temperature ramps between −80 °C and +120 °C with simultaneous six-axis vibration — to identify operational and destructive margins. The purpose is to dramatically accelerate the appearance of latent failures so they can be corrected before series production.
HASS (Highly Accelerated Stress Screening) applies the knowledge gained in HALT as a production filter: each manufactured unit is subjected to an accelerated profile (typically 50 to 80% of the operational margin identified in HALT) to discard units with latent defects before shipping. The HALT+HASS combination does not replace DVT; it complements it.
5. The D2x methodology as structural framework
The previous layers only add value if applied at the right time and with the right criterion. The D2x methodology structures this flow: each of the five phases has an assigned set of simulation and test activities, with quantitative stage-gates between phases that are crossed only when the criteria are met.
“The stage-gate turns the methodology into discipline, not intention. A phase does not close because the calendar has passed; it closes because the metric has been met.”
The V-Model that structures the methodology links each requirement in the descending branch with its corresponding verification phase in the ascending branch. For safety-critical software, the V-Model is a normative requirement: EN 50128 prescribes it for railway software classified SIL1 to SIL4; ISO 26262 for automotive ASIL-A to ASIL-D; and IEC 61508 is the umbrella standard for industrial functional safety.
6. Conclusion
“In custom projects, success at the first prototype is not a goal; it is the minimum threshold of viability. Premium SA has built the simulation and test chain that turns that threshold into reproducible practice.”
The chain described — four layers of simulation, three quantitative reliability tools, two levels of accelerated testing, all structured by the D2x methodology — is Premium SA’s operational answer to a structural constraint: the first prototype must work.
For the customer engineer evaluating providers of custom power electronics, the relevant question is not whether the supplier knows how to design; it is whether the supplier knows how to verify.
References
| Standard / document | Scope |
|---|---|
| Telcordia SR-332 (Issue 4) | Reliability prediction — electronic equipment |
| MIL-HDBK-217F Notice 2 | Reliability prediction — defence |
| Siemens SN29500 | Failure rates — European industrial |
| FIDES Guide 2022 | Reliability methodology — complex environments |
| IEC 61508 | Functional safety — industrial |
| EN 50128:2011 | Railway software — SIL1 to SIL4 |
| ISO 26262 | Automotive functional safety — ASIL-A to ASIL-D |
| CISPR 32 | EMC — multimedia equipment |
| EN 50121-3-2 | EMC — railway rolling stock |
| MIL-STD-461 | EMC — defence equipment |
Talk to our engineering team
Facing a demanding custom specification? Our engineering team can show you how the simulation, reliability and test chain is applied to your converter from the first design gate.
About Premium SA
Premium SA (Premium PSU) is a Barcelona-based designer and manufacturer of custom power supplies and power converters for railway, energy, industrial, data centre and defence applications, with over 40 years of experience since its foundation in 1981. Born in Barcelona, Powering the World.
Application NotesTotal Cost of Ownership (TCO) in Power Electronics: Why the Lowest Price Is Rarely the Best Decision
Total Cost of Ownership (TCO) in Power Electronics: Why the Lowest Price Is Rarely the Best Decision
The hidden costs that never appear on the quotation, a practical framework for calculating TCO and five questions for your next procurement process.
In many competitive evaluations of power converters, unit price is the number-one decision factor, while TCO (Total Cost of Ownership) analysis is applied in only a minority of cases. This means that most purchasing decisions are made without considering the costs that actually determine the long-term economic impact.
This article explains why unit price is a misleading indicator, which hidden costs are usually ignored, and how to apply a practical TCO analysis to your next supplier evaluation.
The iceberg model: what you don’t see is what costs most
The unit price of the converter is the tip of the iceberg: visible, easy to compare and apparently decisive. Beneath the surface, however, there are seven cost categories that in many cases exceed the purchase price by a factor of 3 to 10:
- Cost of field failure. A converter failure on a train does not cost EUR 1,000 for the replacement unit. It costs between EUR 10,000 and 55,000 once you add vehicle downtime (EUR 1,500–5,000/day), technician call-out (EUR 2,000–8,000), urgent shipping of the spare (EUR 500–3,000), root-cause investigation (EUR 5,000–15,000) and contractual service penalties.
- Integration engineering. Changing supplier is not simply swapping one unit for another. It involves requalification, EMC testing, mechanical integration and documentation updates. Typical cost: EUR 30,000–75,000 per model.
- Life-cycle support. A supplier offering 5 years of product availability for a vehicle with a 30-year service life is not saving you money: it is creating an obsolescence problem that will cost more than EUR 50,000 per model when the product is discontinued.
- Warranty and after-sales costs. More restrictive warranty terms (1 year versus 5 years) and longer response times translate into higher operating costs.
- Logistics costs. Lead times of 16 weeks from Asia versus 4 weeks from Europe. Higher safety-stock costs. Risk of delays from sea freight, customs and supply-chain disruption.
- Training and documentation costs. A supplier providing documentation in English, Spanish and German reduces training costs for maintenance staff.
- Supply risk. The 2021–2023 supply-chain crisis showed that dependence on distant suppliers can stall projects for 6–12 months.
How to calculate TCO: a practical framework
Calculating TCO does not have to be complex. For a practical evaluation, use this simplified formula:
TCO = unit price + (NRE / project units) + (failure rate × cost per failure × years of service) + (obsolescence cost / affected units) + logistics delta
Where:
- NRE is the non-recurring engineering cost (integration, qualification, documentation).
- The failure rate is derived from the equipment MTBF.
- The cost per failure includes all direct and indirect costs.
- The obsolescence cost is the redesign required when the product is discontinued.
- The logistics delta is the difference in inventory and transport costs between suppliers.
Example: when the cheapest converter costs twice as much
Consider two quotations for a railway DC/DC converter in a 200-unit project with a 25-year service life:
| Item | Supplier A | Supplier B |
|---|---|---|
| Unit price | EUR 800 | EUR 550 |
| Declared MTBF | 100,000 h (MIL-HDBK-217F, 40 °C) | 60,000 h (Telcordia, 25 °C) |
| Warranty | 5 years | 2 years |
| Product availability | 20+ years | 7 years |
| Lead time | 4 weeks (Europe) | 16 weeks (Asia) |
Supplier B looks 31% cheaper. But when TCO is calculated, Supplier B’s real MTBF (adjusted to MIL-HDBK-217F at 40 °C) is approximately 25,000 hours, which means 4 times more field failures. The total cost of failures over 25 years is 3–5 times the unit-price saving. In addition, Supplier B will require at least 3 obsolescence redesigns over 25 years (cost: EUR 90,000+).
Result: Supplier B’s TCO is 40–60% higher than Supplier A’s.
Five questions for your next procurement process
Build these questions into every power-electronics supplier evaluation:
- Give me the MTBF according to MIL-HDBK-217F at 40 °C ambient. If the supplier cannot or will not, ask yourself why.
- What is your written commitment on spare-part and product availability? Accept only contractual commitments, not verbal ones.
- What is your obsolescence management plan? When a key component reaches end of life, what is the process and who bears the cost of the redesign?
- What is your real lead time and where do you manufacture? If the project cannot absorb a 4-week transport delay, you need European manufacturing.
- Give me a TCO breakdown, not just the unit price. The suppliers who can do this, and are willing to, are the ones worth having as partners.
These five questions will steer your supplier list towards companies that deliver long-term value, not just short-term savings. To go deeper into how reliability is designed in to reduce TCO, see our white paper on reliability in critical power electronics.
Want to apply a TCO analysis to your next supplier evaluation? Our technical team can help you quantify the hidden costs.
About Premium PSU
Premium PSU (Premium SA) designs and manufactures custom power supplies and power converters in Barcelona, with over 40 years of experience in railway, energy, industrial, data centre and defence applications.
Talk to our engineering team
Discuss your power conversion requirements with Premium PSU.