Tag Archive for: EN 50155

white paperWhitepapers

White paper – 40+ Year Reliability in Critical Power Electronics

White Paper · Reliability & RAMS

40+ Year Reliability in Critical Power Electronics: The Premium SA Approach

Physics-of-Failure, DFR methodology, RAMS metrics and PHM — for directors of engineering, procurement and operations

Premium SA
Born in Barcelona, Powering the World
<30%
Acquisition Cost Share of TCO
>10⁶ h
MTBF on Standard Platforms
4 gates
DFR Sequential Quality Gates
+40 yr
Spares Support Commitment

Introduction: From Unit Price to Total Cost of Ownership

White paper – 40+ Year Reliability in Critical Power Electronics

In critical infrastructure — rolling stock, electrical substations, signalling systems, continuous-process plants — the cost of one hour of unavailability far exceeds the price of any electronic converter. Over the last decade, the fraction of total cost of ownership attributable to the acquisition price has fallen below 30% in railway and substation grid applications; the remaining 70% is split between energy consumed, scheduled maintenance, spare parts and, above all, unavailability.

The result is that the purchase decision has migrated from unit price to total cost of ownership. The real question is no

longer “how much does it cost?” but “how long will it last and how will you prove it?”

1. Why Power Electronics Fails — The Physical Mechanisms

Electronic components do not fail randomly: they fail through identifiable, modellable and predictable physical mechanisms. The Physics-of-Failure (PoF) methodology — which Premium SA adopts as primary reference, as opposed to the outdated MIL-HDBK-217F — classifies these mechanisms into four families:

1. Thermo-Mechanical Mechanisms

Dominant in power modules (IGBT, MOSFET, SiC). Every thermal cycle causes materials with different coefficients of thermal expansion (CTE) to expand and contract at different rates, accumulating plastic deformation in solder joints and bond wires.

  • Solder fatigue: Coffin-Manson model: Nf ∝ ΔTj−n with n ≈ 5–7. Increasing Rth(j-c) → vicious circle of rising Tj and accelerating degradation
  • Wire-bond lift-off: Main cause of wear-out failure in traction IGBT modules. Each lost wire increases current in remaining ones, accelerating the next failure

2. Electrical & Dielectric Mechanisms

Active semiconductors age through electrical causes, with no need for thermal cycles. Degradation accumulates during normal operation.

  • TDDB: Gate oxide traps accumulate until resistive conduction path forms. Arrhenius model with electric field accelerator
  • Electromigration: Black model with J² as main variable. Opens voids or creates shorts in metallisation traces
  • Hot Carrier Injection (HCI): Particularly relevant in fast-switching SiC and GaN transistors
  • NBTI/PBTI: Gradual transconductance gm reduction under bias at high temperature

3. Chemical & Environmental Mechanisms

Humidity, contaminants, salts and radiation present in any real installation.

  • Corrosion and electrochemical migration: Dendrite formation (whisker effect) causing intermittent shorts. Peck model (humidity × temperature)
  • Radiation-induced errors (SEU): Cosmic ray neutrons and alpha particles causing Single Event Upsets in memory cells. Mitigated by design: ECC, watchdogs, logical redundancy

4. Mechanical Mechanisms

In railway applications under EN 61373 (category 1B body-mounted), equipment absorbs 5–50 m/s² of random vibration over full life. Critical points: solder joints of heavy components (electrolytics, ferrites, transformers) and connectors. Design control: first mechanical PCB frequency clearly above dominant excitation range (>75 Hz).

2. The Bathtub Curve — Each Phase Calls for a Different Technique

Electronic components exhibit three recognised phases: infant mortality (high initial failure rate from latent manufacturing defects), useful life (low and approximately constant rate), and wear-out (rising rate from accumulation of physical mechanisms). A mature DFR process attacks all three simultaneously.

Technique Phase Addressed When Applied Premium SA Standard
HALT (Highly Accelerated Life Testing) Design margin discovery Design phase on prototypes Combined temperature + vibration stresses beyond specification limits
HASS (Highly Accelerated Stress Screening) Latent manufacturing defects Production screening Stress levels just below operating limit; 100% of production units
Burn-in Infant mortality (left tail) Post-production, pre-delivery 4 h per unit at +60 to +80 °C; extendable to 8 h for long-interval programmes

3. RAMS — The Contractual Language of Reliability

RAMS stands for Reliability, Availability, Maintainability, Safety — the four metrics with which a railway operator or grid DSO measure equipment suitability over its useful life. EN 50126 is the framework standard; EN 50128 and EN 50129 cover software and functional safety respectively.

Reliability

R(t) — probability of surviving to time t. Expressed as MTBF = 1/λ for exponential distribution, or by Weibull parameters (β, η) for wear-out phases. Premium SA calculates MTBF by PoF, not by parts-count (MIL-HDBK-217F).

Availability

A = MTBF / (MTBF + MTTR). For a substation converter with MTBF = 500,000 h and MTTR = 4 h: A ≈ 99.9992%. The key lever is not only increasing MTBF but also reducing MTTR.

Maintainability

Design levers: LRU architecture (front access, two captive screws, keyed connectors), built-in telemetry and self-test, RUL (Remaining Useful Life) estimation via PHM, and 40+ year spares continuity with quarterly obsolescence review.

Safety — EN 50128 / 50129

SIL (Safety Integrity Level) per IEC 61508. PFD (Probability of Failure on Demand) for standby safety functions. SIL 3–4 requires: redundancy, periodic self-test, MC/DC software coverage metrics, formal methods. Premium SA D4Co-SW methodology aligned with EN 50128.

4. The Premium SA DFR Process — Four Sequential Gates

The Design for Reliability (DFR) methodology — originated at the Center of Reliable Power Electronics (CORPE, Aalborg University) and adopted as an internal standard at Premium SA — structures development in four sequential gates with quantitative exit criteria:

Gate Objective Key Activities Exit Criterion
D2W (Design to Work) Functional specification Mission profile definition, requirements capture, architecture selection Signed mission profile + functional test pass
D2F (Design to Function) Derating and PoF analysis Tj_max ≤ 80%, Vop ≤ 80%, thermal simulation, stress analysis All derating targets met; no RPN > 80 open
D4R (Design for Reliability) FMEA, FTA, HALT FMEA bottom-up + FTA top-down; HALT protocol; Coffin-Manson solder analysis RPN > 100 blocked; HALT limits documented; MTBF target verified
D4Co (Design for Compliance) Qualification and FRACAS HASS production screening; burn-in; EMC pre-compliance; EN 50155/EN 61373 qualification All certifications obtained; FRACAS activated; customer RAMS deliverables signed

5. FMEA, FTA and the Analytical Hierarchy

Once derating is established, reliability engineering identifies and mitigates dominant failure modes through three complementary analyses:

  • FMEA/FMECA (Failure Mode and Effects Analysis): Bottom-up. RPN = Severity × Occurrence × Detection (1–10 scale). At Premium SA, any RPN >80 triggers a documented action plan; RPN >100 blocks the D4Co gate.
  • FTA (Fault Tree Analysis): Top-down. Decomposes boolean combinations (AND/OR gates) that may cause system fault. Quantifies impact of redundancies; allows calculation of system-level MTBF.
  • ETA (Event Tree Analysis): Inductive. Models scenarios and responses derived from a single initiating event. Useful for evaluating fault propagation in multi-state systems.

6. Keeping Reliability in Service — PHM, FRACAS and Lean Reliability

PHM — Prognostics and Health Management

The active technical frontier today is the transition from fixed-schedule preventive maintenance towards maintenance based on actual condition. In Premium SA converters:

  • Real-time Tj estimation of semiconductors from Vce_sat and current, with case-temperature compensation
  • Cumulative power-cycle counting with associated ΔTj, to predict RUL (Remaining Useful Life) by PoF models
  • ESR monitoring of capacitors by ripple analysis
  • Periodic export of operating data over communication bus to the operator’s supervisor, with P-F (potential-functional) profile

FRACAS — The Continuous-Learning Loop

Failure Reporting, Analysis and Corrective Action System: every field return is analysed at the appropriate level — LRU, board, component — root cause is identified, and the corrective action is propagated to design and production. The consequence is that the population of installed equipment improves over time rather than degrading. The problem detected in unit #150 is prevented in unit #151.

About Premium SA — Premium SA is a Barcelona-based manufacturer of power electronics converters for railway, industrial and energy applications. Founded in 1981, with more than 900 standard product designs and over 40 years of operational experience, Premium SA supplies DC/DC converters, DC/AC inverters, AC/AC frequency converters, battery chargers, rectifiers and UPS systems from 50 W to 72 kW. All products are designed and manufactured at the Premium SA plant in Barcelona, with capability for EN 50155, EN 50121-3-2, EN 45545-2 and EN 61373 certification. Premium SA serves OEMs and system integrators across Europe through direct sales and a network of specialist distributors — ELIPSE (Benelux), Elma Electronic (Switzerland), RELEC Electronics (United Kingdom), DACPOL (Poland and Central Europe) and ANDA-OLSEN (Scandinavia).

Premium SA  ·  Barcelona, Spain  ·  info@premiumpsu.com  ·  +34 932 232 685  ·  www.premiumpsu.com

© 2026 Premium SA · All rights reserved · Barcelona, Spain
Born in Barcelona, Powering the World
checklistApplication Notes

Buyer’s Guide: Power Conversion Systems for Railway Applications

Buyer’s Guide · EN 50155

Buyer’s Guide: Power Conversion Systems for Railway Applications

EN 50155 and associated standards: everything you need to specify, evaluate and select power supplies, converters and inverters for rolling stock

EN 50155
Core railway standard (2017 revision)
OT1–OT6
Temperature classes −40 °C to +85 °C
25–30 yr
Required rolling stock service life
12
Key supplier questions for qualification

1. Introduction: why this guide matters

The railway sector is one of the most demanding environments for electronic equipment. Power supplies, DC/DC converters, DC/AC inverters, battery chargers and frequency converters operating in rolling stock must withstand extreme conditions of temperature, humidity, vibration, mechanical shock, electromagnetic interference and voltage fluctuations — for 25 to 30 years of service life.

The European standard EN 50155 (equivalent to the international IEC 60571) defines the minimum requirements for this equipment. However, EN 50155 does not operate in isolation: it is complemented by an ecosystem of additional standards — EN 50121 (EMC), EN 45545 (fire protection), EN 61373 (shock and vibration) — that together determine whether a power conversion device is suitable for railway use.

This guide serves two audiences: design engineers who need to correctly specify converters and power supplies, and procurement managers who need objective criteria to evaluate suppliers and make total-cost-of-ownership decisions.

2. The railway standards ecosystem

A power conversion device for railway use must comply with several standards simultaneously, each covering a specific domain:

  • EN 50155:2017 — Core standard: general requirements for all on-board electronics
  • EN 50121-3-2 — Electromagnetic compatibility (EMC) for rolling stock equipment
  • EN 45545-2 — Fire protection and material flammability
  • EN 61373 — Shock and vibration profiles by installation location
  • IEC 60571 — International equivalent to EN 50155
Key point: When requesting a power supply or converter for railway use, it is not enough to ask for “EN 50155 compliance”. You must also specify the EMC requirements (EN 50121-3-2), fire protection (EN 45545-2) and shock/vibration (EN 61373) applicable to the specific equipment location within the vehicle.

3. EN 50155 in detail: key requirements

EN 50155:2017 (replacing the 2007 version) establishes general requirements for all electronic equipment installed on railway rolling stock. For a general introduction to the standard, see What is EN 50155 for railway applications.

  • Supply voltage: continuous, transient and interruption ranges for each nominal voltage
  • Operating temperature: six classes (OT1 to OT6) depending on equipment location
  • Humidity: up to 75% yearly average, 95% for 30 days/year and occasionally 100%
  • Altitude: operation up to 1,400 m (up to 3,000 m under special conditions)
  • Insulation: dielectric strength and insulation requirements between circuits
  • EMC: reference to EN 50121-3-2 for emission and immunity
  • Type tests: full programme including thermal cycling, humidity, shock/vibration and EMC

The 2017 version introduced significant changes: six temperature classes instead of two, more detailed supply interruption requirements, and greater manufacturer/end-user responsibility to define actual operating conditions.

4. Input voltage ranges: classes and tolerances

EN 50155 defines nominal battery voltages of 24, 28, 36, 48, 72, 96 and 110 VDC (recommending 24, 72 or 110 V). For each nominal voltage, the continuous operating range is 0.7 to 1.25 × Unom, and short fluctuations from 0.6 × Unom (0.1 s) up to 1.4 × Unom (1 s) must be withstood without loss of function.

Practical tip: When specifying a converter, always request that the input range covers from brownout (0.6×Unom) to transient overvoltage (1.4×Unom). This ensures full EN 50155 operation without requiring additional external protection circuits.

5. Operating temperature classes (OT1–OT6)

EN 50155:2017 defines six operating temperature classes. The applicable class depends on the equipment location within the vehicle:

  • OT1: −25 °C to +55 °C — passenger compartments and driver’s cabs
  • OT2: −40 °C to +55 °C — passenger compartments and driver’s cabs in cold climates
  • OT3: −25 °C to +70 °C — default class; technical cabinets and equipment compartments
  • OT4: −40 °C to +70 °C — technical cabinets in cold climates
  • OT5: −25 °C to +85 °C — high-temperature locations
  • OT6: −40 °C to +85 °C — high-temperature locations in cold climates
Important: The standard states that OT3 is the default level. If your specification does not indicate a temperature class, the supplier will assume OT3 (−25 °C to +70 °C). Always specify the required class explicitly. Cold-start capability at the minimum class temperature must also be verified during type tests.

6. Supply interruptions and hold-up time

EN 50155 defines mandatory output maintenance during input supply interruptions. It defines interruption classes (S1–S3) and supply change-over classes (C1–C2):

  • S1: no ride-through required during supply interruptions
  • S2: 10 ms interruption without loss of function (default class)
  • S3: 20 ms interruption without loss of function
  • C1: supply change-over at 0.6 Unom for 100 ms, without interruption
  • C2: supply change-over with a 30 ms interruption
Practical tip: S2 (10 ms) is the default interruption class; C1 or C2 apply where the supply changes over between sources. When evaluating offers, ask the supplier how hold-up is achieved: with internal capacitors integrated in the converter, or with external hold-up modules. The integrated solution reduces system BOM and simplifies certification.

7. Complementary standards

EN 50121-3-2 — Electromagnetic compatibility (EMC)

Defines emission and immunity limits for on-board rolling stock equipment. Power converters are among the main sources of EMC interference on board.

  • Conducted emission: limits in the 150 kHz–30 MHz range
  • Radiated emission: limits in the 30 MHz–1 GHz range
  • Immunity: ESD (EN 61000-4-2), fast transients (EN 61000-4-4), radiated (EN 61000-4-3), conducted (EN 61000-4-6)
  • Surge: immunity to surge up to 1 kV (EN 61000-4-5)

EN 45545-2 — Fire protection

Defines the fire behaviour of materials in railway vehicles. Hazard Level (HL1–HL3) classification — most rolling stock requires HL2 or HL3. Tests cover flammability, smoke generation, gas toxicity and burning material dripping.

EN 61373 — Shock and vibration

Defines shock/vibration profiles by installation location:

  • Category 1, Class A: equipment mounted directly on or under the vehicle body
  • Category 1, Class B: equipment mounted inside a cubicle or case that is itself mounted on the vehicle body
  • Category 2: bogie-mounted equipment
  • Category 3: axle-mounted equipment (highest severity)
Always specify the required EN 61373 category and class. A converter qualified for Category 1 (body-mounted) is not automatically suitable for Category 2 (bogie) or Category 3 (axle) installation; severity increases from Category 1 to Category 3.

8. Converter types for railway applications

Power conversion equipment for railway covers a broad range of topologies and functions:

  • DC/DC converters: auxiliary supplies for control electronics, sensors and communications (24–110 V input, 5–48 V outputs, 5 W–1 kW)
  • DC/AC inverters: passenger amenity loads, HVAC auxiliaries, lighting systems (single- or three-phase, 230/400 VAC output)
  • Battery chargers / rectifiers: traction battery and UPS charging, emergency supply (72–110 V input, configurable output)
  • Frequency converters (AC/AC): 50/60 Hz conversion for international rolling stock, fan speed control
  • High-power traction auxiliaries: head-end power, hotel power systems (10–100+ kVA)

Custom engineering is typically required to match the specific form factors, connector layouts, insulation classes and certification requirements of each rolling stock programme.

9. Selection criteria: 12 key questions for your supplier

When evaluating power converter suppliers for railway applications, these 12 questions distinguish a qualified supplier from one that merely claims compliance:

1Certifications: Can you provide EN 50155:2017 type test certificates issued by an accredited laboratory — including EN 50121-3-2, EN 45545-2 and EN 61373?
2Temperature class: For which OT class (OT1–OT6) is the product designed? Have you performed cold-start tests at the minimum temperature?
3Full input range: Does the converter operate from brownout (0.6×Unom, 100 ms) to transient overvoltage (1.4×Unom, 1 s) without external protection circuits?
4Hold-up time: Which interruption classes are supported (S1/S2/S3, C1/C2)? Is hold-up integrated or external?
5Fire protection: Do materials meet EN 45545-2 HL2 or HL3? Provide flammability, smoke and toxicity certificates.
6MTBF / reliability: What is the calculated MTBF per MIL-HDBK-217 or SN 29500? At which ambient temperature?
7Customisation: Can you adapt voltages, power levels, mechanical form factors and connectors to project-specific requirements?
8Manufacturing: Where is the product manufactured? What quality certifications does the plant hold (ISO 9001, IRIS/ISO 22163)?
9Traceability: Do you offer full component and batch traceability for the vehicle lifecycle (25–30 years)?
10Lifecycle support: Do you guarantee product or functional-equivalent availability for 25–30 years?
11Lead times: What are typical lead times for prototypes and series production? Do you offer just-in-time delivery?
12Railway references: Can you provide references with tier-1 OEMs? How many years of railway sector experience do you have?

10. Total cost of ownership (TCO) vs. unit price

One of the most common purchasing mistakes is basing the decision exclusively on unit price. The true cost of a converter over 25–30 years includes:

  • Integration cost: standard converters may require external EMC filters, hold-up modules, mechanical adapters and additional protection circuits — a custom converter eliminates these
  • Certification cost: fewer components = fewer type tests = lower certification cost
  • Field failure cost: higher MTBF = fewer maintenance interventions, less vehicle downtime, fewer contractual penalties
  • NRE engineering cost: amortised over a platform if integration and maintenance savings are significant
  • Obsolescence cost: a supplier guaranteeing 25–30 year lifecycle support avoids costly redesigns
  • Logistics cost: European manufacturing eliminates import tariffs and reduces shipping times
TCO = Unit price + Integration cost + (Cost per failure × Failure rate × Lifetime)
+ Certification cost + Logistics cost + Obsolescence cost

When requesting a quotation, ask the supplier to break down not just the unit price but also the expected MTBF, the integration components required and the long-term support commitment.

11. Specification checklist

Use this checklist when drafting the technical specification for your next railway project:

  • ☐ Nominal input voltage (Unom) and voltage range
  • ☐ Required temperature class (OT1–OT6)
  • ☐ Hold-up class required (S2/C2 or other)
  • ☐ EN 50121-3-2 EMC class
  • ☐ EN 45545-2 Hazard Level (HL2/HL3)
  • ☐ EN 61373 category and class (1A/1B/2)
  • ☐ Output voltage(s), current(s) and power
  • ☐ Isolation requirement (input-to-output)
  • ☐ Mechanical form factor and connector type
  • ☐ IP protection rating required
  • ☐ MTBF target (MIL-HDBK-217 or SN 29500)
  • ☐ Lifecycle support period (25 or 30 years)
  • ☐ Quantity (prototype + series volumes)
  • ☐ Delivery schedule and JIT requirements
  • ☐ Quality certifications required (ISO 9001 / IRIS)
  • ☐ Traceability requirements

12. Glossary

  • DC/DC converter: device converting one DC voltage level to another with galvanic isolation
  • DC/AC inverter: device converting DC (battery) to AC (single- or three-phase)
  • Hold-up time: time during which the output remains within specification after an input power interruption
  • MTBF: Mean Time Between Failures — statistical reliability metric (hours)
  • NRE: Non-Recurring Engineering — one-time design and tooling cost
  • OT class: Operating Temperature class as defined by EN 50155:2017
  • TCO: Total Cost of Ownership — full lifecycle cost including purchase, integration, maintenance and support
  • Type test: formal certification test campaign performed by an accredited laboratory on a representative sample
  • Unom: nominal battery supply voltage (24, 72 and 110 VDC are the most common in railway)

Need guidance for your next railway project?

With over 40 years of experience, more than 900 designs and in-house manufacturing in Barcelona, Premium SA designs power conversion systems for railway, industrial and extreme-environment applications.

Contact our engineering team

About Premium SA — Born in Barcelona, Powering the World. Specialist in custom power conversion systems since 1981, with more than 900 designs, in-house manufacturing in Barcelona and over 40 years serving railway, industrial and extreme-environment applications.
railwayApplication Notes

EN 50155: A Practical Guide to Specifying Railway Electronics

Application Note · Railway

EN 50155: A Practical Guide to Specifying Railway Electronics

Temperature classes, voltage ranges, supply interruptions and companion standards: how to move from “EN 50155 compliant” to an unambiguous specification.

EN 50155:2017 is the European standard that defines the requirements for electronic equipment used on railway rolling stock. Any power converter, inverter, battery charger or electronic system installed on a train in Europe must comply with it. Yet it is in the way compliance is specified that most mistakes are made.

This article explains, in practical terms, how to use EN 50155 to specify the power electronics of a railway project correctly. It is not an academic summary of the standard: it is an operational guide based on what we have learned across hundreds of railway projects. For a general introduction to the standard, see What is EN 50155 for railway applications?

The most common mistake: “EN 50155 compliant”

Specifying that a unit must be “EN 50155 compliant” is like ordering a car “compliant with emissions regulations” without saying whether you need a city runabout or an off-roader. EN 50155 defines a framework of options, and each project must select the right ones. If your specification simply says “EN 50155”, the supplier will choose the options that are easiest (and cheapest) to meet, which may not be the ones your application needs.

Parameter 1: temperature class

EN 50155 defines six temperature classes that set the operating range of the equipment:

Class Operating range Typical application
OT1 −25 °C to +55 °C Passenger compartments and driver’s cabs
OT2 −40 °C to +55 °C Passenger compartments and driver’s cabs in cold climates
OT3 −25 °C to +70 °C Technical cabinets and equipment compartments (default class)
OT4 −40 °C to +70 °C Technical cabinets in cold climates
OT5 −25 °C to +85 °C High-temperature locations (e.g. roof or underframe equipment)
OT6 −40 °C to +85 °C High-temperature locations in cold climates

Choosing the temperature class is not trivial. Our ODS-3000 inverter was originally designed for a lower operating limit of −25 °C. When a rolling-stock manufacturer needed a −40 °C variant for arctic service, we had to change the electrolytic capacitors (standard parts lose 80% of their capacitance at −40 °C), add a pre-conditioning circuit and run a full qualification campaign including 96-hour soaks at −40 °C.

Parameter 2: input voltage range

The standard defines nominal voltage ranges for the train’s DC buses:

Nominal voltage Continuous operating range (0.7–1.25 Un)
24 Vdc 16.8 – 30.0 Vdc
48 Vdc 33.6 – 60.0 Vdc
72 Vdc 50.4 – 90.0 Vdc
96 Vdc 67.2 – 120.0 Vdc
110 Vdc 77.0 – 137.5 Vdc

Short fluctuations from 0.6 Un (0.1 s) up to 1.4 Un (1 s) must also be withstood. The converter must operate correctly across the whole specified range, including the transient conditions defined in the standard. Always specify the full range, not just the nominal voltage.

Parameter 3: supply interruption class

EN 50155 defines how equipment must behave when the supply is briefly interrupted (for example, when crossing a neutral section or when the pantograph loses contact with the overhead line):

  • S1: no ride-through. The unit shuts down and restarts when the supply returns.
  • S2: 10 ms ride-through. Withstands short interruptions without restarting.
  • S3: 20 ms ride-through.

For critical systems (protection, communications, signalling), S2 or S3 is usual. For comfort systems (passenger sockets, non-essential lighting), S1 may be acceptable.

Beyond EN 50155: the companion standards

EN 50155 is not the only applicable standard. All railway electronic equipment must also comply with:

  • EN 50121-3-2: electromagnetic compatibility (EMC). The electromagnetic environment on a train is extremely harsh.
  • EN 45545-2: fire protection. Materials must meet specific requirements for flammability, smoke emission and toxicity.
  • EN 61373: shock and vibration. Vibration levels on rolling stock are significantly more severe than in industrial applications.

Make sure your specification covers all four standards. A unit that meets EN 50155 but not EN 45545-2 cannot be installed on a European train.

How to specify correctly: a practical summary

For your next project, include at least the following in the specification:

  1. Temperature class (OT1–OT6).
  2. Nominal voltage and full operating range.
  3. Supply interruption class (S1/S2/S3).
  4. EMC requirements (EN 50121-3-2).
  5. Fire class (EN 45545-2, stating the hazard level HL1/HL2/HL3).
  6. Vibration category (EN 61373: Cat. 1 body-mounted (Class A or B), Cat. 2 bogie-mounted, Cat. 3 axle-mounted).

With these six parameters clearly defined, you will receive comparable quotations and avoid the surprises that appear when a specification is ambiguous. Need help specifying EN 50155 power electronics? Our technical team in Barcelona can advise you.

About Premium PSU

Premium PSU (Premium SA) designs and manufactures custom power supplies and power converters in Barcelona, with over 40 years of experience in railway, energy, industrial, data centre and defence applications.

Talk to our engineering team

Discuss your power conversion requirements with Premium PSU.

Contact us