Buyer’s Guide: Power Conversion Systems for Railway Applications

Buyer’s Guide · EN 50155

Buyer’s Guide: Power Conversion Systems for Railway Applications

EN 50155 and associated standards: everything you need to specify, evaluate and select power supplies, converters and inverters for rolling stock

EN 50155
Core railway standard (2017 revision)
OT1–OT6
Temperature classes −40 °C to +85 °C
25–30 yr
Required rolling stock service life
12
Key supplier questions for qualification

1. Introduction: why this guide matters

The railway sector is one of the most demanding environments for electronic equipment. Power supplies, DC/DC converters, DC/AC inverters, battery chargers and frequency converters operating in rolling stock must withstand extreme conditions of temperature, humidity, vibration, mechanical shock, electromagnetic interference and voltage fluctuations — for 25 to 30 years of service life.

The European standard EN 50155 (equivalent to the international IEC 60571) defines the minimum requirements for this equipment. However, EN 50155 does not operate in isolation: it is complemented by an ecosystem of additional standards — EN 50121 (EMC), EN 45545 (fire protection), EN 61373 (shock and vibration) — that together determine whether a power conversion device is suitable for railway use.

This guide serves two audiences: design engineers who need to correctly specify converters and power supplies, and procurement managers who need objective criteria to evaluate suppliers and make total-cost-of-ownership decisions.

2. The railway standards ecosystem

A power conversion device for railway use must comply with several standards simultaneously, each covering a specific domain:

  • EN 50155:2017 — Core standard: general requirements for all on-board electronics
  • EN 50121-3-2 — Electromagnetic compatibility (EMC) for rolling stock equipment
  • EN 45545-2 — Fire protection and material flammability
  • EN 61373 — Shock and vibration profiles by installation location
  • IEC 60571 — International equivalent to EN 50155
Key point: When requesting a power supply or converter for railway use, it is not enough to ask for “EN 50155 compliance”. You must also specify the EMC requirements (EN 50121-3-2), fire protection (EN 45545-2) and shock/vibration (EN 61373) applicable to the specific equipment location within the vehicle.

3. EN 50155 in detail: key requirements

EN 50155:2017 (replacing the 2007 version) establishes general requirements for all electronic equipment installed on railway rolling stock. For a general introduction to the standard, see What is EN 50155 for railway applications.

  • Supply voltage: continuous, transient and interruption ranges for each nominal voltage
  • Operating temperature: six classes (OT1 to OT6) depending on equipment location
  • Humidity: up to 75% yearly average, 95% for 30 days/year and occasionally 100%
  • Altitude: operation up to 1,400 m (up to 3,000 m under special conditions)
  • Insulation: dielectric strength and insulation requirements between circuits
  • EMC: reference to EN 50121-3-2 for emission and immunity
  • Type tests: full programme including thermal cycling, humidity, shock/vibration and EMC

The 2017 version introduced significant changes: six temperature classes instead of two, more detailed supply interruption requirements, and greater manufacturer/end-user responsibility to define actual operating conditions.

4. Input voltage ranges: classes and tolerances

EN 50155 defines nominal battery voltages of 24, 28, 36, 48, 72, 96 and 110 VDC (recommending 24, 72 or 110 V). For each nominal voltage, the continuous operating range is 0.7 to 1.25 × Unom, and short fluctuations from 0.6 × Unom (0.1 s) up to 1.4 × Unom (1 s) must be withstood without loss of function.

Practical tip: When specifying a converter, always request that the input range covers from brownout (0.6×Unom) to transient overvoltage (1.4×Unom). This ensures full EN 50155 operation without requiring additional external protection circuits.

5. Operating temperature classes (OT1–OT6)

EN 50155:2017 defines six operating temperature classes. The applicable class depends on the equipment location within the vehicle:

  • OT1: −25 °C to +55 °C — passenger compartments and driver’s cabs
  • OT2: −40 °C to +55 °C — passenger compartments and driver’s cabs in cold climates
  • OT3: −25 °C to +70 °C — default class; technical cabinets and equipment compartments
  • OT4: −40 °C to +70 °C — technical cabinets in cold climates
  • OT5: −25 °C to +85 °C — high-temperature locations
  • OT6: −40 °C to +85 °C — high-temperature locations in cold climates
Important: The standard states that OT3 is the default level. If your specification does not indicate a temperature class, the supplier will assume OT3 (−25 °C to +70 °C). Always specify the required class explicitly. Cold-start capability at the minimum class temperature must also be verified during type tests.

6. Supply interruptions and hold-up time

EN 50155 defines mandatory output maintenance during input supply interruptions. It defines interruption classes (S1–S3) and supply change-over classes (C1–C2):

  • S1: no ride-through required during supply interruptions
  • S2: 10 ms interruption without loss of function (default class)
  • S3: 20 ms interruption without loss of function
  • C1: supply change-over at 0.6 Unom for 100 ms, without interruption
  • C2: supply change-over with a 30 ms interruption
Practical tip: S2 (10 ms) is the default interruption class; C1 or C2 apply where the supply changes over between sources. When evaluating offers, ask the supplier how hold-up is achieved: with internal capacitors integrated in the converter, or with external hold-up modules. The integrated solution reduces system BOM and simplifies certification.

7. Complementary standards

EN 50121-3-2 — Electromagnetic compatibility (EMC)

Defines emission and immunity limits for on-board rolling stock equipment. Power converters are among the main sources of EMC interference on board.

  • Conducted emission: limits in the 150 kHz–30 MHz range
  • Radiated emission: limits in the 30 MHz–1 GHz range
  • Immunity: ESD (EN 61000-4-2), fast transients (EN 61000-4-4), radiated (EN 61000-4-3), conducted (EN 61000-4-6)
  • Surge: immunity to surge up to 1 kV (EN 61000-4-5)

EN 45545-2 — Fire protection

Defines the fire behaviour of materials in railway vehicles. Hazard Level (HL1–HL3) classification — most rolling stock requires HL2 or HL3. Tests cover flammability, smoke generation, gas toxicity and burning material dripping.

EN 61373 — Shock and vibration

Defines shock/vibration profiles by installation location:

  • Category 1, Class A: equipment mounted directly on or under the vehicle body
  • Category 1, Class B: equipment mounted inside a cubicle or case that is itself mounted on the vehicle body
  • Category 2: bogie-mounted equipment
  • Category 3: axle-mounted equipment (highest severity)
Always specify the required EN 61373 category and class. A converter qualified for Category 1 (body-mounted) is not automatically suitable for Category 2 (bogie) or Category 3 (axle) installation; severity increases from Category 1 to Category 3.

8. Converter types for railway applications

Power conversion equipment for railway covers a broad range of topologies and functions:

  • DC/DC converters: auxiliary supplies for control electronics, sensors and communications (24–110 V input, 5–48 V outputs, 5 W–1 kW)
  • DC/AC inverters: passenger amenity loads, HVAC auxiliaries, lighting systems (single- or three-phase, 230/400 VAC output)
  • Battery chargers / rectifiers: traction battery and UPS charging, emergency supply (72–110 V input, configurable output)
  • Frequency converters (AC/AC): 50/60 Hz conversion for international rolling stock, fan speed control
  • High-power traction auxiliaries: head-end power, hotel power systems (10–100+ kVA)

Custom engineering is typically required to match the specific form factors, connector layouts, insulation classes and certification requirements of each rolling stock programme.

9. Selection criteria: 12 key questions for your supplier

When evaluating power converter suppliers for railway applications, these 12 questions distinguish a qualified supplier from one that merely claims compliance:

1Certifications: Can you provide EN 50155:2017 type test certificates issued by an accredited laboratory — including EN 50121-3-2, EN 45545-2 and EN 61373?
2Temperature class: For which OT class (OT1–OT6) is the product designed? Have you performed cold-start tests at the minimum temperature?
3Full input range: Does the converter operate from brownout (0.6×Unom, 100 ms) to transient overvoltage (1.4×Unom, 1 s) without external protection circuits?
4Hold-up time: Which interruption classes are supported (S1/S2/S3, C1/C2)? Is hold-up integrated or external?
5Fire protection: Do materials meet EN 45545-2 HL2 or HL3? Provide flammability, smoke and toxicity certificates.
6MTBF / reliability: What is the calculated MTBF per MIL-HDBK-217 or SN 29500? At which ambient temperature?
7Customisation: Can you adapt voltages, power levels, mechanical form factors and connectors to project-specific requirements?
8Manufacturing: Where is the product manufactured? What quality certifications does the plant hold (ISO 9001, IRIS/ISO 22163)?
9Traceability: Do you offer full component and batch traceability for the vehicle lifecycle (25–30 years)?
10Lifecycle support: Do you guarantee product or functional-equivalent availability for 25–30 years?
11Lead times: What are typical lead times for prototypes and series production? Do you offer just-in-time delivery?
12Railway references: Can you provide references with tier-1 OEMs? How many years of railway sector experience do you have?

10. Total cost of ownership (TCO) vs. unit price

One of the most common purchasing mistakes is basing the decision exclusively on unit price. The true cost of a converter over 25–30 years includes:

  • Integration cost: standard converters may require external EMC filters, hold-up modules, mechanical adapters and additional protection circuits — a custom converter eliminates these
  • Certification cost: fewer components = fewer type tests = lower certification cost
  • Field failure cost: higher MTBF = fewer maintenance interventions, less vehicle downtime, fewer contractual penalties
  • NRE engineering cost: amortised over a platform if integration and maintenance savings are significant
  • Obsolescence cost: a supplier guaranteeing 25–30 year lifecycle support avoids costly redesigns
  • Logistics cost: European manufacturing eliminates import tariffs and reduces shipping times
TCO = Unit price + Integration cost + (Cost per failure × Failure rate × Lifetime)
+ Certification cost + Logistics cost + Obsolescence cost

When requesting a quotation, ask the supplier to break down not just the unit price but also the expected MTBF, the integration components required and the long-term support commitment.

11. Specification checklist

Use this checklist when drafting the technical specification for your next railway project:

  • ☐ Nominal input voltage (Unom) and voltage range
  • ☐ Required temperature class (OT1–OT6)
  • ☐ Hold-up class required (S2/C2 or other)
  • ☐ EN 50121-3-2 EMC class
  • ☐ EN 45545-2 Hazard Level (HL2/HL3)
  • ☐ EN 61373 category and class (1A/1B/2)
  • ☐ Output voltage(s), current(s) and power
  • ☐ Isolation requirement (input-to-output)
  • ☐ Mechanical form factor and connector type
  • ☐ IP protection rating required
  • ☐ MTBF target (MIL-HDBK-217 or SN 29500)
  • ☐ Lifecycle support period (25 or 30 years)
  • ☐ Quantity (prototype + series volumes)
  • ☐ Delivery schedule and JIT requirements
  • ☐ Quality certifications required (ISO 9001 / IRIS)
  • ☐ Traceability requirements

12. Glossary

  • DC/DC converter: device converting one DC voltage level to another with galvanic isolation
  • DC/AC inverter: device converting DC (battery) to AC (single- or three-phase)
  • Hold-up time: time during which the output remains within specification after an input power interruption
  • MTBF: Mean Time Between Failures — statistical reliability metric (hours)
  • NRE: Non-Recurring Engineering — one-time design and tooling cost
  • OT class: Operating Temperature class as defined by EN 50155:2017
  • TCO: Total Cost of Ownership — full lifecycle cost including purchase, integration, maintenance and support
  • Type test: formal certification test campaign performed by an accredited laboratory on a representative sample
  • Unom: nominal battery supply voltage (24, 72 and 110 VDC are the most common in railway)

Need guidance for your next railway project?

With over 40 years of experience, more than 900 designs and in-house manufacturing in Barcelona, Premium SA designs power conversion systems for railway, industrial and extreme-environment applications.

Contact our engineering team

About Premium SA — Born in Barcelona, Powering the World. Specialist in custom power conversion systems since 1981, with more than 900 designs, in-house manufacturing in Barcelona and over 40 years serving railway, industrial and extreme-environment applications.
railwayApplication Notes

EN 50155: A Practical Guide to Specifying Railway Electronics

Application Note · Railway

EN 50155: A Practical Guide to Specifying Railway Electronics

Temperature classes, voltage ranges, supply interruptions and companion standards: how to move from “EN 50155 compliant” to an unambiguous specification.

EN 50155:2017 is the European standard that defines the requirements for electronic equipment used on railway rolling stock. Any power converter, inverter, battery charger or electronic system installed on a train in Europe must comply with it. Yet it is in the way compliance is specified that most mistakes are made.

This article explains, in practical terms, how to use EN 50155 to specify the power electronics of a railway project correctly. It is not an academic summary of the standard: it is an operational guide based on what we have learned across hundreds of railway projects. For a general introduction to the standard, see What is EN 50155 for railway applications?

The most common mistake: “EN 50155 compliant”

Specifying that a unit must be “EN 50155 compliant” is like ordering a car “compliant with emissions regulations” without saying whether you need a city runabout or an off-roader. EN 50155 defines a framework of options, and each project must select the right ones. If your specification simply says “EN 50155”, the supplier will choose the options that are easiest (and cheapest) to meet, which may not be the ones your application needs.

Parameter 1: temperature class

EN 50155 defines six temperature classes that set the operating range of the equipment:

Class Operating range Typical application
OT1 −25 °C to +55 °C Passenger compartments and driver’s cabs
OT2 −40 °C to +55 °C Passenger compartments and driver’s cabs in cold climates
OT3 −25 °C to +70 °C Technical cabinets and equipment compartments (default class)
OT4 −40 °C to +70 °C Technical cabinets in cold climates
OT5 −25 °C to +85 °C High-temperature locations (e.g. roof or underframe equipment)
OT6 −40 °C to +85 °C High-temperature locations in cold climates

Choosing the temperature class is not trivial. Our ODS-3000 inverter was originally designed for a lower operating limit of −25 °C. When a rolling-stock manufacturer needed a −40 °C variant for arctic service, we had to change the electrolytic capacitors (standard parts lose 80% of their capacitance at −40 °C), add a pre-conditioning circuit and run a full qualification campaign including 96-hour soaks at −40 °C.

Parameter 2: input voltage range

The standard defines nominal voltage ranges for the train’s DC buses:

Nominal voltage Continuous operating range (0.7–1.25 Un)
24 Vdc 16.8 – 30.0 Vdc
48 Vdc 33.6 – 60.0 Vdc
72 Vdc 50.4 – 90.0 Vdc
96 Vdc 67.2 – 120.0 Vdc
110 Vdc 77.0 – 137.5 Vdc

Short fluctuations from 0.6 Un (0.1 s) up to 1.4 Un (1 s) must also be withstood. The converter must operate correctly across the whole specified range, including the transient conditions defined in the standard. Always specify the full range, not just the nominal voltage.

Parameter 3: supply interruption class

EN 50155 defines how equipment must behave when the supply is briefly interrupted (for example, when crossing a neutral section or when the pantograph loses contact with the overhead line):

  • S1: no ride-through. The unit shuts down and restarts when the supply returns.
  • S2: 10 ms ride-through. Withstands short interruptions without restarting.
  • S3: 20 ms ride-through.

For critical systems (protection, communications, signalling), S2 or S3 is usual. For comfort systems (passenger sockets, non-essential lighting), S1 may be acceptable.

Beyond EN 50155: the companion standards

EN 50155 is not the only applicable standard. All railway electronic equipment must also comply with:

  • EN 50121-3-2: electromagnetic compatibility (EMC). The electromagnetic environment on a train is extremely harsh.
  • EN 45545-2: fire protection. Materials must meet specific requirements for flammability, smoke emission and toxicity.
  • EN 61373: shock and vibration. Vibration levels on rolling stock are significantly more severe than in industrial applications.

Make sure your specification covers all four standards. A unit that meets EN 50155 but not EN 45545-2 cannot be installed on a European train.

How to specify correctly: a practical summary

For your next project, include at least the following in the specification:

  1. Temperature class (OT1–OT6).
  2. Nominal voltage and full operating range.
  3. Supply interruption class (S1/S2/S3).
  4. EMC requirements (EN 50121-3-2).
  5. Fire class (EN 45545-2, stating the hazard level HL1/HL2/HL3).
  6. Vibration category (EN 61373: Cat. 1 body-mounted (Class A or B), Cat. 2 bogie-mounted, Cat. 3 axle-mounted).

With these six parameters clearly defined, you will receive comparable quotations and avoid the surprises that appear when a specification is ambiguous. Need help specifying EN 50155 power electronics? Our technical team in Barcelona can advise you.