{"id":24681,"date":"2026-11-11T15:04:41","date_gmt":"2026-11-11T14:04:41","guid":{"rendered":"https:\/\/premiumpsu.com\/?p=24681"},"modified":"2026-11-11T15:04:41","modified_gmt":"2026-11-11T14:04:41","slug":"pdr-110k-power-shelf-800vdc-data-centers-ia","status":"publish","type":"post","link":"https:\/\/premiumpsu.com\/es\/resources-news\/pdr-110k-power-shelf-800vdc-data-centers-ia\/","title":{"rendered":"Premium PSU lanza el PDR-110K: power shelf de 110kW a 800Vdc para data centers de IA"},"content":{"rendered":"<div class=\"pp-wp-article\" style=\"font-family: Verdana, Geneva, sans-serif; font-size: 14px; line-height: 1.7; color: #1a1a2e; background: #fff;\"> <header style=\"background: linear-gradient(135deg, #143A80 0%, #1e4fa0 60%, #0a2a60 100%); color: #fff; padding: 48px 56px 36px;\"> <div style=\"display: inline-block; background: #D4A020; color: #fff; font-size: 10px; font-weight: bold; letter-spacing: 2px; text-transform: uppercase; padding: 4px 14px; border-radius: 2px; margin-bottom: 18px;\">Lanzamiento \u00b7 Data Center<\/div> <h1 style=\"font-size: 28px; font-weight: bold; line-height: 1.25; margin-bottom: 10px; color: white!important;\">Premium PSU lanza el PDR-110K: power shelf de 110kW a 800Vdc para data centers de IA<\/h1> <p style=\"font-size: 15px; color: rgba(255, 255, 255, 0.82); margin-bottom: 0; font-style: italic;\">Un power shelf AC\/DC modular de 3RU que convierte una alimentaci\u00f3n trif\u00e1sica en un bus regulado de 800Vdc para racks de IA y alta densidad.<\/p> <\/header> <div style=\"padding: 40px 56px;\"> <p style=\"margin: 0 0 16px;\">Premium PSU presenta el <strong><a style=\"color: #143a80;\" href=\"https:\/\/premiumpsu.com\/es\/producto\/pdr-110k-power-shelf-acdc-110kw-800vdc\/\">PDR-110K<\/a><\/strong>, un power shelf modular de 3RU que convierte una alimentaci\u00f3n trif\u00e1sica AC en un <strong>bus regulado de 800Vdc<\/strong>. Un solo shelf entrega hasta <strong>110kW<\/strong> mediante seis m\u00f3dulos rectificadores hot-plug de 18,5kW, gestionados por un controlador tambi\u00e9n hot-plug. Est\u00e1 dise\u00f1ado para racks de servidores de IA y alta densidad en centros de datos hyperscale, de colocation y corporativos.<\/p> <h2 id=\"por-que-800vdc\" style=\"font-size: 17px; font-weight: bold; color: #143a80; margin: 40px 0 14px; padding-bottom: 6px; border-bottom: 2px solid #D4A020;\">Por qu\u00e9 800Vdc en el rack de IA<\/h2> <p style=\"margin: 0 0 16px;\">La potencia por rack en los data centers de IA no deja de crecer y el sector est\u00e1 llevando la distribuci\u00f3n a tensiones DC m\u00e1s altas; por ejemplo, NVIDIA ha presentado una <a style=\"color: #143a80;\" href=\"https:\/\/blogs.nvidia.com\/blog\/800-vdc-power-architecture-ai-factory\/\" target=\"_blank\" rel=\"noopener\">arquitectura de 800 VDC para AI factories<\/a>. La raz\u00f3n es la corriente.<\/p> <p style=\"margin: 0 0 16px;\">Distribuir la potencia a 800Vdc en lugar de un bus de baja tensi\u00f3n reduce la corriente para la misma potencia en un factor aproximado de 15. A 110kW, la salida del PDR-110K transporta unos <strong>139A<\/strong> (a 790Vdc), mientras que un bus de 52Vdc necesitar\u00eda unos <strong>2.115A<\/strong>. Una corriente menor permite usar barras y cables de menor secci\u00f3n y reduce las p\u00e9rdidas por conducci\u00f3n en el rack. Lo explicamos en detalle en <a style=\"color: #143a80;\" href=\"https:\/\/premiumpsu.com\/es\/resources-news\/arquitectura-800-vdc-centros-datos-ia\/\">La revoluci\u00f3n del 800 VDC<\/a>.<\/p> <h2 id=\"prestaciones\" style=\"font-size: 17px; font-weight: bold; color: #143a80; margin: 40px 0 14px; padding-bottom: 6px; border-bottom: 2px solid #D4A020;\">Qu\u00e9 ofrece el PDR-110K<\/h2> <ul style=\"margin: 0 0 16px; padding-left: 20px;\"> <li style=\"margin-bottom: 6px;\"><strong>110kW por shelf<\/strong> de 415 a 528Vac entre fases; 100kW de 311 a 415Vac.<\/li> <li style=\"margin-bottom: 6px;\"><strong>Amplio rango de entrada trif\u00e1sica:<\/strong> 311 \u2026 528Vac entre fases, trif\u00e1sica + PE, 50\/60Hz.<\/li> <li style=\"margin-bottom: 6px;\"><strong>Regulaci\u00f3n precisa:<\/strong> 810Vdc en vac\u00edo y 790Vdc a plena carga, precisi\u00f3n de \u00b10,25% al 100% de carga, rizado y ruido \u22648Vp-p.<\/li> <li style=\"margin-bottom: 6px;\"><strong>Rectificadores eficientes:<\/strong> cada m\u00f3dulo de 18,5kW alcanza una eficiencia &gt;97% entre el 50 \u2026 100% de carga y un PF \u22650,98 entre el 20 \u2026 100% de carga.<\/li> <li style=\"margin-bottom: 6px;\"><strong>Compacto:<\/strong> 3RU, flujo de aire frontal-trasero con ventiladores de velocidad variable controlados internamente.<\/li> <\/ul> <h2 id=\"operacion\" style=\"font-size: 17px; font-weight: bold; color: #143a80; margin: 40px 0 14px; padding-bottom: 6px; border-bottom: 2px solid #D4A020;\">Pensado para la disponibilidad y la operaci\u00f3n del data center<\/h2> <p style=\"margin: 0 0 16px;\">Los m\u00f3dulos rectificadores y el controlador son <strong>hot-plug<\/strong>: un m\u00f3dulo puede sustituirse en funcionamiento mientras el resto reparte la carga. El controlador ofrece telemetr\u00eda a trav\u00e9s de un puerto Ethernet RJ45 con <strong>Redfish y SNMP<\/strong> northbound y PMBus\/SMBus hacia los rectificadores, adem\u00e1s de interfaz Web GUI, LEDs de estado de tres colores y bot\u00f3n de reset. El firmware del controlador y de los rectificadores se puede actualizar en campo mediante bootloader.<\/p> <p style=\"margin: 0 0 16px;\">El shelf dispone tambi\u00e9n de <strong>interfaz para unidad de respaldo por bater\u00edas (BBU)<\/strong>. Sobre el papel de las BBU y el almacenamiento en los transitorios de cargas de IA, consulta <a style=\"color: #143a80;\" href=\"https:\/\/premiumpsu.com\/es\/resources-news\/lic-bbu-transitorios-sidecar-800v\/\">LIC, BBU y la ventana de 1\u201350 ms<\/a>; sobre los protocolos de gesti\u00f3n de convertidores, <a style=\"color: #143a80;\" href=\"https:\/\/premiumpsu.com\/es\/resources-news\/convertidores-gestionables-pmbus-redfish-scmi\/\">Convertidores de potencia gestionables: PMBus, Redfish y SCMI<\/a>.<\/p> <h2 id=\"escalabilidad\" style=\"font-size: 17px; font-weight: bold; color: #143a80; margin: 40px 0 14px; padding-bottom: 6px; border-bottom: 2px solid #D4A020;\">Escalable de 110kW a 660kW<\/h2> <p style=\"margin: 0 0 16px;\">Hasta <strong>seis shelves PDR-110K pueden trabajar en paralelo<\/strong> con reparto de corriente, alcanzando un total de hasta 660kW. La potencia del rack puede crecer en escalones de 110kW con el mismo shelf y la misma interfaz de gesti\u00f3n.<\/p> <h2 id=\"especificaciones\" style=\"font-size: 17px; font-weight: bold; color: #143a80; margin: 40px 0 14px; padding-bottom: 6px; border-bottom: 2px solid #D4A020;\">Especificaciones principales<\/h2> <table style=\"width: 100%; border-collapse: collapse; margin: 0 0 20px; font-size: 13px;\"> <tbody> <tr style=\"background: #143a80; color: #fff;\"> <th style=\"text-align: left; padding: 8px 12px;\">Par\u00e1metro<\/th> <th style=\"text-align: left; padding: 8px 12px;\">PDR-110K<\/th> <\/tr> <tr> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">Rango de tensi\u00f3n de entrada<\/td> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">311 \u2026 528Vac entre fases, trif\u00e1sica + PE, 50\/60Hz<\/td> <\/tr> <tr style=\"background: #f4f6fa;\"> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">Tensi\u00f3n de salida<\/td> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">800Vdc nominal (810Vdc en vac\u00edo \/ 790Vdc a plena carga)<\/td> <\/tr> <tr> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">Potencia nominal de salida<\/td> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">110kW a 415 \u2026 528Vac; 100kW a 311 \u2026 415Vac<\/td> <\/tr> <tr style=\"background: #f4f6fa;\"> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">M\u00f3dulos rectificadores<\/td> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">6 \u00d7 18,5kW, hot-plug<\/td> <\/tr> <tr> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">Funcionamiento en paralelo<\/td> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">Hasta 6 shelves (hasta 660kW)<\/td> <\/tr> <tr style=\"background: #f4f6fa;\"> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">Monitorizaci\u00f3n<\/td> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">Ethernet RJ45, Redfish \/ SNMP, Web GUI, interfaz BBU<\/td> <\/tr> <tr> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">Tama\u00f1o y refrigeraci\u00f3n<\/td> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">3RU, 830 \u00d7 438 \u00d7 131mm, flujo de aire frontal-trasero<\/td> <\/tr> <tr style=\"background: #f4f6fa;\"> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">Condiciones ambientales<\/td> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">-5 \u2026 +45\u00b0C, hasta 3050m, IP20<\/td> <\/tr> <tr> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">Fiabilidad y normativa<\/td> <td style=\"padding: 7px 12px; border-bottom: 1px solid #e3e7ef;\">MTBF \u2265300.000h; dise\u00f1ado para cumplir los requisitos cULus, CE y RoHS<\/td> <\/tr> <\/tbody> <\/table> <div style=\"background: #f4f6fa; border-top: 3px solid #D4A020; padding: 20px 24px; margin: 32px 0 0;\"> <p style=\"margin: 0 0 8px; font-weight: bold; color: #143a80;\">\u00bfDise\u00f1ando una arquitectura de rack a 800Vdc?<\/p> <p style=\"margin: 0;\">Descarga el <a style=\"color: #143a80;\" href=\"https:\/\/premiumpsu.com\/datasheets\/PDR-110K.pdf\" target=\"_blank\" rel=\"noopener\">datasheet del PDR-110K<\/a>, consulta la <a style=\"color: #143a80;\" href=\"https:\/\/premiumpsu.com\/es\/producto\/pdr-110k-power-shelf-acdc-110kw-800vdc\/\">ficha de producto<\/a> o contacta con nuestro departamento comercial para tu proyecto de data center. Algunas referencias est\u00e1n sujetas a MOQ y plazos de entrega especiales.<\/p> <\/div> <\/div> <\/div>","protected":false},"excerpt":{"rendered":"<p>Premium PSU lanza el PDR-110K, un power shelf modular de 3RU que entrega 110kW a 800Vdc con seis rectificadores hot-plug de 18,5kW, para racks de IA y centros de datos de alta densidad.<\/p>\n","protected":false},"author":2,"featured_media":24668,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_acf_changed":false,"footnotes":""},"categories":[1163,757],"tags":[1337,1394,1398,1172,1395,1396,1397],"class_list":["post-24681","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-data-center-es","category-eventos-y-noticias-corporativas","tag-800-vdc","tag-ai-data-centers","tag-centros-de-datos","tag-data-center-ia","tag-data-center-power","tag-pdr-110k","tag-power-shelf"],"acf":[],"_links":{"self":[{"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/posts\/24681","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/users\/2"}],"replies":[{"embeddable":true,"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/comments?post=24681"}],"version-history":[{"count":1,"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/posts\/24681\/revisions"}],"predecessor-version":[{"id":24682,"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/posts\/24681\/revisions\/24682"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/media\/24668"}],"wp:attachment":[{"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/media?parent=24681"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/categories?post=24681"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/premiumpsu.com\/es\/wp-json\/wp\/v2\/tags?post=24681"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}